**Password Setup**
Enter a new password for this
controller and press ENTER:
New Password: 0000
**DIAGNOSTICS**
For Qualified Technician Use Only:
(1)Power Ventilation Auxilary SWX:
(2)Ignore Inlet #1 Auxiliary SWX = Yes
(3)Ignore Inlet #2 Auxiliary Swx = Yes
(4)Natural Ventilation Auxiliary SWX:
(5)Ignore Unit #1 Auxiliary SWX = Yes
(6)Ignore Unit #2 Auxiliary Swx = Yes
(7)Feed Level Sensor:
(8)Maximum Range = 26.00 ft
(9)Dead Zone = 1.50 ft
(10)GPAD12 = 115
GPAD13 = 105
GPAD14 = 98
GPAD15 = 90
(11)Soft Resets = 0
(12)Voltage Resets = 0
(13)Hard Resets = 0
(3) Copy to Program –
Enter the COPY TO program
number (0, 1, or 2).
(4) Enter to Proceed –
When “Enter to Proceed” is selected
and the ENTER button is pressed, the Copy to Program
number programming contents is replaced with the
programming contents of the Seasonal Program number.
NOTE:
This action is not reversible.
(5) Change Password –
Select “Change Password” for changing the existing password for the Controller.
The four digits will allow a numeric password from 0001 to 9999. Changing the Password to 0000
disables the locks until the password is changed to a number between 0001 and 9999.
NOTE:
Record the password in a convenient retrievable location
.
7.14 Diagnostics
The Diagnostics screen is for qualified technician use only and can only be changed by using the service
code. Contact the local dealer for assistance.
(1)
Power Ventilation Auxiliary
SWX -
Setting these options to Yes
will ignore the indication from the
curtain switch. This feature will
totally ignore the auxiliary switches
on the PT machines when answered
yes.
Note:
This must be answered 'No' and
the open auxiliary switch of the
vent machine must be connected
in order to use the feature of
running the tunnel curtain with
the vents during Power
ventilation when the pressure is
to high and the vents are
completely open.
(2)
Ignore Inlet #1 Auxiliary Switch -
Yes or No
(3)
Ignore Inlet #2 Auxiliary Switch -
Yes or No
(4)
Natural Ventilation Auxiliary SWX -
Setting these options to Yes will ignore the indication from the
curtain switch. This feature will totally ignore the auxiliary switches on the PT machines when
answered "Yes".
Note:
The auxiliary switches must be connected and this answered to no in order for the control to enter
into natural ventilation.
(5)
Ignore Unit #1 Auxiliary Switch -
Yes or No
(6)
Ignore Unit #2 Auxiliary Switch -
Yes or No
(7)
Feed Level Sensor
– Settings for setting the maximum range and calibration of the feed level sensor.
(8)
Maximum Range -
Total sensing range of the sensor.
(9)
Dead Zone -
Distance from the top of the feed bin to the bottom of the sensor.