Part No. 4801-5331 Rev 2-2015
Evolution 1200
14 of 65
Inlet Conditions
#
STATUS MODE
PRESS
OPENED
CLOSED
U1
Close
Vent
0.00
No
No
U2
Close
Tun
0.00
No
No
#
STATUS MODE
RTEMP
ON
OFF
TIME
-----------
TARGET
70°
---------
V1
0%
CTUN
79.4°
89.4
89.0 Ramp
V2
0%
Cstir
79.6°
89.4
89.0
None
1
On
Light
Ramp
2
On
Cstir
79.6°
76°
95°
None
.
.
.
.
.
.
.
16
On
Cstir
79.6°
76°
95°
Min1
Inlet Conditions
(1)# (2)STATUS
(3)MODE (4)PRESS (5)OPENED
(6)CLOSED
U1
Open
Vent
0.04
No
No
U2
Close
Tun
0.04
No
Yes
.
.
.
.
.
.
.
.
.
.
.
.
.
.
(15) Cool Timer:
Cool timer is also allowed a
different timer cycle if needed. This can be used
for foggers or cool cell systems.
(16) Max Run -
The Cool Timer Maximum Run
Time percentage.
(17) Cycle -
Cycle Time in Minutes. Cool timer is
also allowed a different timer cycle if needed.
This will be used for foggers or cool cell
systems.
(18) Min Run -
The Cool Timer Minimum Run Time
percentage.
6.4
Stage Conditions
When the Stage Conditions screen is selected by using the Navigator Select arrows, the following menu
screen is shown. Use the up and down arrows in the Editor to view the desired information. Notice that the
Light Clock and Feed Clock Stages are listed after the Inlet Conditions section. The Heat Stages are then
displayed in order of increasing ON Temperatures. The Cool stages, including the Variable Output stages,
are listed below the Target Line in order of increasing ON Temperatures.
6.4.1 Inlet Conditions
The Inlet Conditions part of the Stage Conditions screen is used to control Power Trak operation for power
ventilation. U1 is normally for baffle boards and U2 controls tunnel inlets.
(1) #-
The stage bank either U1 or U2.
(2) Status -
Indicates if the Stage is Off, Opening or Closing.
(3) Mode
– The mode column tells you how the machine will be operating. If it will be a vent machine
"VENT" or a tunnel machine "TUN" machine.
(4) Pressure
– Indicates the pressure in the building.
(5) Opened –
Indicates if the machine is fully open (Yes or No). When the machine is fully open on the
open auxiliary switch, this column will indicate a “Yes”.
(6) Closed –
Indicates if the machine is fully closed (Yes or No). When the machine is fully closed on the
closed auxiliary switch, this column will indicate a “Yes”.