Part No. 4801-5331 Rev 2-2015
Evolution 1200
24 of 65
** (1)EV1200 v0.34 **
(2)HHNet Address = 1
(3)Optimum Mode = Off
(3)Growout Start Date = 15 Jun 2003
(4)Preheat Mode = Off
(5)Date = 21 Feb 2007
(6)Day = Wed
(7)Time = 05:20p
(8)Units of Measure = English
(9)Pressure Units = Inches of wc
(10)Water Meter-Pulses Per Unit - 100
**SENSOR SETUP**
(1)Room Temperature Sensors = --6-4-2-
(2)ALARM on Outside Sensor Error = Off
(3)SENSOR (4)ENABLED (5)VALUE (6)ADJUSTED
1 ON 77.0 + 3.0°
2 ON 77.0° + 1.0°
3 ON 77.0° +00.0°
4 OFF 77.0° +00.0°
5 OFF 77.0° +00.0°
6 OFF 77.0° +00.0°
7 OFF 77.0° +00.0°
8 OFF 77.0° +00.0°
OUT ---- 77.0° +00.0°
7. Setting Programming Functions
This section discusses the programming screens for the Evolution 1200.
7.1
General Settings
The General Settings contains parameters that usually only need to be set once when the system is installed.
To change any of these parameters, use the EDITOR arrows to navigate through the list and the plus (+) and
minus (-) buttons to increase or decrease the values.
(1)
Software Version
– The software version currently in use.
(2)
HHNET Address
- HH.Net permits up to
32 controllers to be addressed on a single
communications port of a personal
computer (PC). In order for the computer
to recognize the communications from the
controllers, each controller must have a
unique network address. For example: If
you have an Evolution 1200, a Stage
Master, and two Power Vents you would
need to set the Evolution to address 1, the
Stage Master to address 2, the first Power
Vent to address 3, and the second Power
Vent to address 4. Valid settings are: 1 -
32. (You do not have to address the
controllers in any particular order.)
(3)
Optimum Mode
– On or Off. Refer to
Section 7.6.2
for a detailed description of
the Optimum Mode features and options
(4)
Growout Start Date -
Set the date desired
to start the grow-out. Evolution will use this
date to control the feed, light clock and
ramping functions. NOTE: This must be set
to the first day of grow-out. Your historical
data will start at this date and go for 99 days
or until the next grow-out date has been set
and then that date has been passed.
(5)
Preheat Mode
–
On or Off
(6)
Date –
The current date as Day/Month/Year.
(7)
Day –
The current day of the week.
(8)
Time –
The current time.
(9)
Units of Measure -
The units of measure can be
selected as English or Metric.
(10)
Pressure Units -
Pressure units can be selected
as inches of water column or Pascals.
(11)
Water Meter-Pulses Per Unit –
HH standard
water meter is one pulse per gallon. Select a
value from 1 to 100.
7.2
Temperature Sensors
The Sensor Set-Up screen is used to set the temperature sensors that will be used to determine the internal
temperature of the building.
(1)
Room Temperature Sensors -
Select any or
all of the internal sensors. Your alarm high
and low limits will use these sensors that are
displayed here.
For example: If you wanted to display
sensors 1,2,3,4,5 for your room temperature
it would look like this: "---54321" If you
turn all the sensors off (by setting it to -) the
control would use the outside temperature
and it would look like this: "Outside-".
(2)
Alarm on Outside Sensor Error
–
On or Off.
(3)
Sensor –
Identifies up to eight inside and one
outside sensor.
(4)
Enabled –
Yes or No.
(5)
Value –
Current temperature reading.
(6)
Adjusted –
This will indicate if the sensor temperature has been calibrated and the amount of re-calibration.