Water Filters
Test Description
Display Information
Action Trigger
Start Test Mode
All LCD segments lit
DIP switch #1 set to on, all others off
Software version
Software version #
Press a key after entering test mode as
above
Enter test mode
Blank Display
Press a key after displaying the software
version #.
DIP switch #2
Display to show “2”
Turn on DIP switch #2
Display to Blank
Turn off DIP switch #2
DIP switch #3
Display to show “3”
Turn on DIP switch #3
Display to Blank
Turn off DIP switch #3
DIP switch #4
Display to show “4”
Turn on DIP switch #4
Display to Blank
Turn off DIP switch #4
DIP switch #5
Display to show “5”
Turn on DIP switch #5
Display to Blank
Turn off DIP switch #5
DIP switch #6
Display to show “6”
Turn on DIP switch #6
Display to Blank
Turn off DIP switch #6
DIP switch #7
Display to show “7”
Turn on DIP switch #7
Display to Blank
Turn off DIP switch #7
DIP switch #8
Display to show “8”
Turn on DIP switch #8
Display to Blank
Turn off DIP switch #8
Status Key
Display to show “11”
Press Status Key
+ Key
Display to show “12” and motor to run for
15 seconds
Press + Key
- Key
Display to show “13” (and turns on Chlo-
rinator output for 15 seconds IF chlorina-
tor is connected)
Press - Key
Regen Key
Display to show “14”
Press Regen Key
Home Switch
Display to show “H” when Home switch
closed
Close Home Switch
Display to Blank when open
Open Home Switch
Position Switch
Display to show “P” when Position switch
closed
Close Position Switch
Display to Blank when open
Open Position Switch
Flow Meter
Display to show “Phone” icon when flow
meter is connected
Connect Flow Meter
Display to blink “Phone” icon when flow
meter is sending pulses
Spin Flow Meter
Chlorinator
Display to show “Colon” icon when chlori-
nator is connected
Connect Chlorinator
Display to blink “Colon” icon when chlori-
nator is turned on
Turn on Chlorinator when the plus key is
pressed.
When exiting test mode, if the dip switches or sensors have not changed, the control is to restore all values from EEPROM, and
resume where it left off after homing. If the dip switch or sensors have change, the values should reset to factory defaults. In either
case the valve should home itself upon exit of test mode.