Settline Time
This setting is used to set the time in minutes for cycle 2. This cycle is a settling time
for filters. The display will show “br” in the left most digits and the cycle time in the
right most digits. Adjust the value with the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next programming step.
Fast Rinse Time
This setting is used to set the time in minutes forcycle 3. The display will show “Fr”
in the left most digits and then the cycle time in the right most digits. Adjust the value
with the “+” or “-” keys. Pressing the “Status” key will save the setting and move to the
next programming step.
Regeneration Interval
This setting is used to set the days between regeneration in time clock mode. The
display will show “REG” icon and “dAY” for two seconds and then display the numbers
to change. Adjust the value with the “+” or “-” keys.
Pressing the “Status” key will save the setting and move to the next programming step.
Immediate Regeneration Override
This setting is used to determine whether an immediate or delayed regeneration
should occur after a power outage greater than 3 hours. It applies only when dip #2 is
set for “delay”. The display will show the REG icon and “dEL” or Id” depending on the
last saved setting (default to “dEL” if EEPROM has no saved value). Toggle between
“dEL” and “Id” with the “+” or “-” key.
If set to “dEL”, then after power outage greater than 3 hours the “regen” icon will light
and the regeneration will begin when the timer reaches the next programmed time of
regeneration.
If set to “Id”, then after a power outage greater than 3 hours the regeneration will begin
as soon as the control completes the homing cycle.
Pressing the “Status” key will save the setting and go to the next Hidden Menu setting.
Programming
21
Blank Display
After the last programming menu is displayed (menu will vary depending on mode of
operation), pressing status will move to a blank display screen.
From the ‘blank display’, pressing the “+” key from the blank display will enter the diagnostics menu.
From the ‘blank display’, pressing the “-” key will enter the statistics menu.
From the ‘blank display’, pressing the “Status” key will exit programming mode and return to the service mode time display.
The “regen” key is ignored while in the ‘blank display’.
Hidden Programming Menu
(Accessed from the regular time of day display in service mode by holding the “+” key for 5 seconds).