CTC GSi 16
External heat source
Charge start ºC
70
Stop diff.
5
Smart block cap.
Off
Save settings
Here your own settings can be stored; confirm with the
“OK” button.
Load settings
The saved settings can be reloaded using this option.
Load factory settings
The product is supplied with the factory values set. They
can be restored by activating this function. Press OK to
confirm. The language, product and product size are
retained.
12.14 External heat source
(EHS)
Charge start °C
70
This is the minimum temperature required in the external
heat source tank (B47) for the mixing valve to open and
emit heat to the system.
Stop diff (°C)
5
Temperature difference
before charging stops from
the
extra heating source.
Smart block cap.
Off(On/Off)
Electric operation prioritised. The shunt on the EHS tank
is closed to accumulate heat energy.
Read more in the “Smartgrid” section.
12.15 EcoVent (accessory)
EcoVent
The menu becomes active once the CTC EcoVent
ventilation product has been defined. For information
on possible settings, please refer to the CTC EcoVent
manual.
Summary of Contents for GSi 16
Page 6: ...6 CTC GSi 16...
Page 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Page 49: ...49 CTC GSi 16...
Page 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Page 51: ...51 CTC GSi 16...
Page 53: ...53 CTC GSi 16...
Page 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Page 61: ...61 CTC GSi 16...
Page 119: ......