13.2 Alarm messages
If a fault occurs with e.g. a sensor, an alarm is triggered. A message appears on the display with
information about the fault.
You reset the alarm by pressing the Reset Alarm button on the display. If several alarms are triggered,
they are displayed one after the other. A persisting fault must first be rectified before it can be reset.
Some alarms are reset automatically if the fault ceases.
Alarm: [E055] Incorrect phase sequence
Reset alarm
Alarm messages
Description
[E010] Compressor type ?
This message appears if no information about the compressor type is
available.
[E013] EVO off
This message appears when there is a fault with the expansion valve control.
[E024] Fuse blown
This message appears when the fuse (F1, F2) has been triggered.
[E026] Heat pump
This message appears if the heat pump is in alarm mode.
[E027] Communication error
HP
[E063] Comm. err. relay board
[E063] Comm. err. motor
protection
[E086] Comm. err. expansion
card
This message appears if the display card (A1) is unable to communicate with
the HP control card (A5).
This message appears if the display card (A1) is unable to communicate with
the relay board (A2).
This message appears if the HP control card (A5) is unable to communicate
with the motor protection (A4).
This message appears if the display card (A1) is unable to communicate with
CTC Solar Control/Expansion Card (A3).
[E035] High pressure switch
The refrigerant’s high pressure switch has been triggered. Press reset and
check whether the alarm recurs. If the fault recurs, contact your installer.
[E040] Low brine flow
Low brine flow is often caused by air in the collector system, especially
immediately following installation. Collectors which are too long can also be a
cause. Press reset and check whether the alarm recurs. Also check the brine
filter that has been installed.
If the fault recurs, contact your installer.
[E041] Low brine temp.
Incoming brine temperatures from bore hole/ground loop are too low. Press
reset and check whether the alarm recurs. If the fault recurs, contact your
installer to check the positioning of the cold side.
[E044] Stop, high comp. temp.
This message appears when the compressor temperature is high.
Press reset and check whether the alarm recurs. If the fault recurs, contact
your installer.
[E045] Stop, low evaporation
This message appears when the evaporation temperature is low.
Press reset and check whether the alarm recurs. If the fault recurs, contact
your installer.
[E046] Stop, high evaporation
This message appears when the evaporation temperature is high.
Press reset and check whether the alarm recurs. If the fault recurs, contact
your installer.
[E047] Stop, low suct. gas exp.
valve
This message appears when the suction gas temperature is low.
Press reset and check whether the alarm recurs. If the fault recurs, contact
your installer.
Summary of Contents for GSi 16
Page 6: ...6 CTC GSi 16...
Page 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Page 49: ...49 CTC GSi 16...
Page 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Page 51: ...51 CTC GSi 16...
Page 53: ...53 CTC GSi 16...
Page 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Page 61: ...61 CTC GSi 16...
Page 119: ......