78
CTC GSi 16
Heating circuit
Max primary flow ºC
60
Min primary flow ºC
Off
Heating, mode
Auto
Heating, mode, ext
Heating off, out ºC
18
Heating off, time
120
Inclination ºC
50
Adjustment ºC
0
Night reduction disable ºC
-14
Room temp reduced ºC
-2
or
Primary flow reduced ºC
-3
Alarm room temp ºC
5
Smart low price ºC
1
Smart over capacity ºC
2
Max time heating
20
Charge pump %
60
Drying period mode
Off
Drying period temp ºC
25
Inclination (default setting)
50 (25—85)
Inclination means the temperature your property needs
at different outdoor temperatures. See more detailed
information in the section “Your home’s heating
settings”. The value set corresponds to the temperature
of the radiators when the outdoor temperature is -15°C.
After this default setting, fine adjustment takes place in
the “Room temperature” menu.
Inclination adjustment
0 (-20—20)
Inclination adjustment means that the overall
temperature level can be raised or lowered at all outdoor
temperatures. After this default setting, fine adjustment
takes place in the “Room temperature” menu.
Night reduction of °C
5 (-40—40)
When the outdoor temperature is lower than the preset
value, the night reduction stops as too much energy
is consumed and it takes a long time to increase the
temperature. This menu overrides remote control.
Room temp reduced
-2 (0—-40)
“Room temp reduced” is displayed if a room sensor is
installed.
This setting defines how many degrees the room
temperature will be reduced by during the various
scheduled reduction periods, e.g. Night reduction,
Holiday, etc.
Primary flow reduced
-3 (0—-40)
If there is no room sensor installed, “Primary flow
reduced” is displayed instead.
Alarm, low room temp °C
5 (-40 —40)
When the room temperature becomes lower than the
preset value, ”Alarm, low room temp °C” is displayed.
Smart Low price °C
1 (Off/1—5)
Setting to increase inclination adjustment at energy
price “Low price”, via Smartgrid. Read more in the
“Smartgrid” section.
Smart over capacity °C
2 (Off/1—5)
Setting to increase inclination adjustment at energy
price “Over capacity”, via Smartgrid. Read more in the
“Smartgrid” section.
Max. time Heating
20 (10—120)
This is the maximum time (minutes) during which the
heat pump charges the heating circuit if needed in the
hot water tank.
Charge pump %
60 (25—100)
Setting for charge pump (G11) speed (percent) when
charging the heating circuit.
Summary of Contents for GSi 16
Page 6: ...6 CTC GSi 16...
Page 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Page 49: ...49 CTC GSi 16...
Page 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Page 51: ...51 CTC GSi 16...
Page 53: ...53 CTC GSi 16...
Page 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Page 61: ...61 CTC GSi 16...
Page 119: ......