Dag
1 2 3 4 5 6 7 8 9
osv
ºC
#1.
#2.
#1.
#3.
#2. 10 dagar
58 ºC
-5 ºC
Room temp.
DHW
Operation
Drying period active
1 /
12
(25)
CTC GSi 12
Monday 09:35
CTC GSi 16
Drying period mode
Off(Off/1/2/3)
Floor drying function for newly-built properties.
The function limits the calculation of primary flow
temperature (setpoint) for “Your home’s heating
settings” to the schedule below.
Mode 1
Floor drying function for 8 days.
#1. Heating circuit setpoint is set at 25 °C for 4 days.
#2. Days 5-8 use preset value
Drying period temp °C.
From Day 9 onwards the value is calculated
automatically according to “Your home’s heating
settings”.
Mode 2
Drying period for 10 days + stepped increase and
decrease.
#1. Stepped increase start. The setpoint for the
heating circuit is set to 25 °C. The setpoint is then
raised by 5 °C each day until it is equal to the
Drying
period temp °C.
The final step may be less than 5 °C.
#3. Stepped decrease. After the stepped increase
and 10 days at an even temperature, the temperature
setpoint is reduced to 25 °C in daily 5 °C stages.
The final step may be less than 5 °C.
Following the stepped decrease and one day at the
setpoint of 25 °C, the value is calculated automatically
according to “Your home’s heating settings”.
Mode 3
This mode starts with Mode 1, followed by Mode 2
and finally by “Your home’s heating settings”.
Drying period temp °C
25 (25—55)
Here you set the temperature for #2 as shown above.
Example for Mode 1 with
Drying period temp °C: 38 °C.
“Your home’s heating settings”
“Your home’s heating settings”
Example for Mode 2 with
Drying period temp °C: 37 °C.
Example of operation data for Mode 2, Day 1 of 12
with current setpoint (25) °C.
30
20
Day
1 2
3
4 5 6 7 8 9 10 11 12 13
and so on
30
20
°C
40
40
Summary of Contents for GSi 16
Page 6: ...6 CTC GSi 16...
Page 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Page 49: ...49 CTC GSi 16...
Page 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Page 51: ...51 CTC GSi 16...
Page 53: ...53 CTC GSi 16...
Page 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Page 61: ...61 CTC GSi 16...
Page 119: ......