M
M
MP
MP
B30
G30
Y11
B31
Y31
Y11
G31
B47
B41
Y41
Y11
G46
Y11
B42
01
02
G32
F2
F3
B7
Schematic diagram only The installation engineer fits expansion tank, safety valves, bleeders, etc. and sizes the
system.
System 2
System 2 is a system structure with solar heat connected to an external heat
source tank (EHS-tank) and an extra buffer tank (CTC EcoTank for example).
The system allows for a larger solar collector surface since it carries a greater
volume of water.
Charging conditions
Charging starts when B31 is 7°C warmer than B42.
Buffer tank
without
coil:
Charging stops when there is a difference of 3°C between B31/B30 or when
the charge temperature is reached.
Buffer tank
with
coil:
For a tank with a solar coil, the charging stops instead when B31 is 3°C
warmer than B42.
Charging of the EHS tank compares sensor B41 to sensor B47.
The buffer tank (02) may also have a solar coil; this means that the heat
exchanger (F2), pump (G32) or non-return valve (Y11) is not required.
Summary of Contents for GSi 16
Page 6: ...6 CTC GSi 16...
Page 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Page 49: ...49 CTC GSi 16...
Page 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Page 51: ...51 CTC GSi 16...
Page 53: ...53 CTC GSi 16...
Page 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Page 61: ...61 CTC GSi 16...
Page 119: ......