Heat pump
Settings language
Compressor: Permitted
Brine pump on
Auto
Tariff HP
Off
Smart block HP
Off
Start at degree minute
-60
Max rps
100
Max rps silent mode
50
Timer Silent mode
Max rps silent mode 2
50
Timer Silent mode 2
Settings language
12.6 Heat pump
Compressor Permitted/Blocked
The product is supplied with a blocked compressor.
Since the compressor is blocked, the product operates
like an electric boiler with full functionality. Permitted
means that the compressor is allowed to operate.
Brine pump on
Auto/10d/On
After installation, you can choose to run the brine pump
as follows:
•
10d: runs constantly for 10 days to remove air from
the system, after which the pump returns to auto
mode.
•
Till: continuous brine pump operation.
•
Auto: the brine pump (G20) runs simultaneously
with the compressor.
Tariff HP
Off(On/Off)
Find out more in the section titled “Define remote
control”.
Smart blocking HP
Off(On/Off)
Read more in the “Smartgrid” section.
Start at degree minute
-60 (-900—-30)
This states the degree minute at which the heat pump
will start.
Max. RPS
80 (50—80)
Sets the maximum permitted compressor speed.
Summary of Contents for GSi 16
Page 6: ...6 CTC GSi 16...
Page 48: ...48 CTC GSi 16 8 13 Tank schematic diagram A2...
Page 49: ...49 CTC GSi 16...
Page 50: ...50 CTC GSi 16 8 14 HP cooling module schematic diagram A5...
Page 51: ...51 CTC GSi 16...
Page 53: ...53 CTC GSi 16...
Page 54: ...54 CTC GSi 16 M GF B25 B26 Y21 B5 G20 B24 B23 B27 B28 G11 G5 B102 B18...
Page 61: ...61 CTC GSi 16...
Page 119: ......