1.3
Standards compliance
CSMIO/IP-M controllers were designed and made in accordance with the national and international
standards for industrial control systems based on electronic components:
•
Detailed requirements for programmable controllers: working characteristics, shock resistance,
safety etc. EN61131-2 (IEC1131-2), CSA 22.2, UL508
•
Compliance with European Guidelines (low voltage, the level of electromagnetic interference
Electromagnetic Compability
), the CE marking.
•
Electrical and non-combustible properties of insulation materials: UL 746C, UL 94, etc.
•
The Product
made in lead-free technology
, RoHS compliant.
1.4
Specification
Parameter
Value
Digital inputs
12
Digital outputs
4
Relay outputs
2
Analog inputs
2
Analog outputs
2
Supply voltage
24VDC +/-10%
Power consumption
5W
Maximum I/O Voltage
30VDC
Maximum output line load
250mA
Analog Input Voltage
0-10VDC
Analog Output - Maximum Load
5mA
Axis Drives control type
(STEP/DIR)
Maximum frequency of the STEP signal
125kHz
STEP Signal Duty Cycle
50%
PC communications
Ethernet 10/100Mb
Ambient temperature range
0
o
C to +60
o
C
Relative Humidity (Non-Condensing)
10% to 95%
(without condensation)
The STEP outputs signal frequency is in no way limited by the „Kernel speed” settings in Mach3 program.
While using the CSMIO/IP-M controller this Mach3’s configuration parameter is unused and can be set at
any value.
C S - L a b s . c . – C N C C S M I O / I P - M c o n t r o l l e r
Page 6