MODELS
Cf1 (MIAMI) & MANHATTAN
GAS TYPE
NATURAL GAS ONLY
SUPPLY PRESSURE
20 mbar
CATEGORY
I2H
INJECTOR
440
GAS CONNECTION
8mm COMPRESSION
HIGH HEAT INPUT
6.9kW (gross)
LOW HEAT INPUT
2.9kW
WEIGHT
25 KG
EFFICIENCY
CLASS 1
9 issue 5
IMPORTANT:
This appliance is fitted with a spillage monitoring system, (ODS) and must not be adjusted, bypassed or
put out of operation, by the user or installer. Any parts of this system should only be exchanged for genuine crystal
manufacture parts.
This fire must not be installed in a room that contains a bath or shower.
This fire cannot be installed onto a combustible wall. All combustible materials must be removed from the area shown in
Fig 11:1/11:1a
No combustible materials must be present in the builders opening.
These Instructions must be left with the User.
Keep any Plastic Bags away from Children.
VENTILATION :GB
For installation in Great Britain additional ventilation is not normally required unless indicated as being required by the
‘Spillage Test’
VENTILATION : IE
For installation in Southern Ireland ventilation must be in accordance with I.S813 Domestic Gas Installations.
8.Technical data