CRYSTAL CF1/MANHATTAN
1:1
This fire should be installed and serviced every 12months in accordance with current gas safety
(installation and uses) regulations by a competent person who is a member of a recognised gas installer’s
organisation (e.g. Gas safe ) and in accordance with the installation instructions.
1:2
The flue should be inspected before your appliance is installed and checked annually to ensure continuous
clearance of combustion products and safe operation.
Where solid fuel has been used the chimney must be swept before installation.
1:3
UNDER NO CIRCUMSTANCES
must the fire be used if the glass door panel is broken cracked or
damaged
1:4
IMPORTANT.
The glass panel door and other outer parts, (e.g. outer frame and door) will become hot in use; clothes
etc., should not be wrapped over or near the fire and we recommend that a ‘fire guard conforming to BS
8423 should be used for the protection of young children the elderly the infirm and pets’.
1:5
DO NOT
burn paper or rubbish in the fire.
1:6
It is important for the safe operation and to maintain efficiency that the fire is not operated with damaged or
broken fuel effect pieces or ceramics.
UNDER NO CIRCUMSTANCES
should extra fuel effect pieces be used.
1:7
When the fire is first used it may emit a slight odour or smoke, this is due to the newness and will
disappear.
DO NOT WASH OR VACUUM
the Fuel Effect ceramic pieces.
1:8
The fire
MUST
be installed into a Builders Opening in line with the Installation Instructions.
No combustible material should be placed within 150mm of the appliance
Any combustible material above the opening should be removed up to a height of
500mm. any shelf above the fire should not project more than 150mm forward.
For deeper shelves allow a 15mm increase in height for every 25mm in depth.
1:9
These instructions are intended to assist you in the correct operation of your appliance and
Should be kept safe for future reference
3 issue 5
USERS INSTRUCTIONS
1.IMPORTANT NOTES