190913-24 SPNE 5055.101.B

MODEL:

SUPER  INSERT

DESIGN-E

SPNE

SAFETY NOTICE

If this stove is not properly installed, a house 

fi re may result. For your safety, follow the 

installation directions. Consult local building 

inspector or officials about restrictions and 

installation inspection requirements in your 

area.

Super Insert

IMPORTANT:

THESE INSTRUCTIONS ARE TO 
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS

INSTALLATION 
AND OPERATING 
INSTRUCTIONS

TESTED and LISTED 
to ULC S628 / UL 1482

Meets the U.S. Environmental Protection 
Agency's July 1990 Particulate Emission
Standards 

SERIAL #

Summary of Contents for SUPER INSERT DESIGN-E SPNE

Page 1: ...nsult local building inspector or officials about restrictions and installation inspection requirements in your area Super Insert IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THE...

Page 2: ...ustion Air 12 Operation 13 Wood Selection 13 How to Test Your Wood 13 Lighting the Fire 13 Normal Operation 13 Restarting After Extended or Overnight Burns 13 Over Firing 13 More Wood More Heat 14 Pro...

Page 3: ...als about restric tions and installation inspection requirements in your area Clearances Masonry or Factory Built Fireplace Theminimumrequiredclearancestosurroundingcombustible materialswheninstalledi...

Page 4: ...ket Baffle Top heat shield and mounting bolt Baffle Gasket Brick Rails Manifold Some warping of the baffle is normal up to 1 4 or 65cm Replace if the baffle has permanent warping greater than this or...

Page 5: ...t embers by non combustible material extending 16 USA and 18 CANADA to the firing side and 8 to other sides of the unit Consult CAN CSA B365 Installation Code for Solid Fuel Burning appliances and equ...

Page 6: ...6 SPNE 190913 24 43 3 8 6 1 2 29 3 16 23 3 4 21 1 2 21 1 8 36 8 3 4 20 3 4 18 28 1 8 9 1 2 10 21 Dimensions...

Page 7: ...een in use for some time The existing fireplace damper is to be locked open or removed completely WARNING Do not remove bricks or mortar from your existing fireplace Exception Masonry or steel includi...

Page 8: ...pe Note A clean out door may be required under local codes when a direct flue connection is used Consult local codes 3 Push the Insert into position inside the fireplace and at tach the connector pipe...

Page 9: ...and thermal snap switch Take note of where the wires are routed and secured They must be positioned correctly to avoid damage 3 Loosen the two bolts that secure the ash lip to the firebox carefully l...

Page 10: ...ch Fig 16 refit ash lip sides and top Ensure that the power cable is correctly routed through the surround and it is not touching the firebox side Wire placement is important to prevent damage to wire...

Page 11: ...on page 9 and then remove the decorative top by loosening the two wing bolts underneath and sliding it out of the brackets Fig 18 4 Slide the assembled surround from the top down and engage in slots...

Page 12: ...as described in the installation section When the installation is complete do not seal surround to fireplace This will allow enough combustion air to enter the fireplace cavity and the Insert Removal...

Page 13: ...ion after a good coal base exists and wood has charred Normal Operation 1 Set air control to desired setting If smoke pours down across the glass waterfall effect this indicates you have shut the cont...

Page 14: ...ood will be producing 9375 BTU s per hour 7500 BTU x 10 lbs 8 hrs 9375 BTU s per hr If you put 20 lbs of wood in your stove for an eight hour burn you will get 18 750 BTU s per hr 7500 BTU x 20 lbs 8...

Page 15: ...ning requires small fuel loads two or three logs at a time or 1 4 to 1 2 of a fuel load and leaving the air inlet relatively wide open especially during the first 10 to 30 minutes after each loading w...

Page 16: ...it must be replaced before using the stove Re placement glass can be obtained from your Dealer The size required is 8 13 16 x 15 1 4 x 5 mm Ceramic glass must be used Do not substitute with any other...

Page 17: ...Handle Assembly WODC 4147C 13 Flame Shield WINS 4513 14 Replacement Baffle Kit SSER DBAKIT 15 Brick Rail Set SSER RAILSET 16 Firebrick Set BRIC SSERA 17 Boost Manifold 4105 18 O A Cover 4557 19 Air S...

Page 18: ...a heat storage and the thermalinsulationkeepsthecombustionzonehot Active flamingtakesplaceduringthefirstpartoftheburn During this stage heat is stored in the mass of the unit and is later released sl...

Page 19: ...Door Gasket leakage Replace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Area too large 4 Poor insulation or open concrete Won t Burn Overnight...

Page 20: ...lation This package contains 18 full size firebricks as well as 1 cut size brick With the heater in the upright position install firebricks as follows Place firebricks on the bottom of the heater firs...

Page 21: ...21 SPNE 190913 24 NOTES...

Page 22: ...22 SPNE 190913 24 NOTES...

Page 23: ...V9L 6V8 INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY S INSTALLATION AND OPERATING INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES RESTRICTIONS AND INSTALLATION INSPECTION...

Page 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD www pacificenergy net Phone 1 250 748 1184 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...