47
45
16-325
16-390
16-455
16-520
16-585
61
IGNITION MODULE MOUNTING BRACKET
905000
1
1
1
1
1
62
IGNITION MODULE, S8610M 1011 (STD ONLY)
3505015
1
1
1
1
1
63
3505555
1
1
1
1
1
64
GAS VALVE TRAIN ASSEMBLY (NAT GAS) (STD ONLY)
-
1
1
1
1
1
64
GAS VALVE TRAIN ASSEMBLY (LP GAS) (STD ONLY)
-
1
1
1
1
1
65
OPERATING LIMIT L4080D1218
35-3300
1
1
1
1
1
66
3/4" NPT X 3" IMMERSION WELL
35-1010
1
1
1
1
1
67
BLOCKED VENT SWITCH
960123
1
1
1
1
1
*
960010
1
1
1
1
1
*
IGNITION MODULE HARNESS (STD ONLY)
9605100
1
1
1
1
1
*
WIRE HARNESS ASSEMBLY (STD ONLY)
9605120
1
1
1
1
1
*
GROUND WIRE
9601101
1
1
1
1
1
*
36" IGNITION CABLE
3501136
1
1
1
1
1
*
GAS VALVE TRAIN ASSEMBLY (NAT GAS) (CSD-1 ONLY)
-
-
-
1
1
1
*
GAS VALVE TRAIN ASSEMBLY (LP GAS) (CSD-1 ONLY)
-
-
-
1
1
1
*
IGNITION MODULE, UT 1003-612A (CSD-1 ONLY)
3503100
-
-
1
1
1
*
DAUGHTER BOARD, UT 1145-2 (CSD-1 ONLY)
3503105
-
-
1
1
1
*
310200
-
-
1
1
1
*
DAUGHTER BOARD COVER (CSD-1 ONLY)
310205
-
-
1
1
1
*
PILOT VALVE (CSD-1 ONLY)
3503107
-
-
1
1
1
*
RV12L PILOT REGULATOR - NAT/LP (CSD-1 ONLY)
3503115
-
-
1
1
1
*
900460
-
-
1
1
1
*
WIRE HARNESS ASSEMBLY (CSD-1 ONLY)
9605920
-
-
1
1
1
*
GAS VALVE HARNESS (CSD-1 ONLY)
9605900
-
-
1
1
1
*
ALARM HARNESS (CSD-1 ONLY - PURPLE)
9605902
-
-
2
2
2
*
"R-STAT" JUMPER HARNESS (CSD-1 ONLY - GRAY)
9605907
-
-
1
1
1
*
9605905
-
-
1
1
1
*
CSD-1 WIRING LABEL (CSD-1 ONLY)
980965
-
-
1
1
1
*
INSTALLATION MANUAL
980416
1
1
1
1
1
*
980446
1
1
1
1
1
NOTE: SOME STANDARD FITTINGS USED ON CSD-1 MODEL BOILERS NOT LISTED - PROCURE THESE LOCALLY
* NOT PICTURED
STRAIN RELIEF BUSHING FOR BLOCKED VENT SWITCH WIRING
"PILOT COMPRESSION" x 1/8" MNPT ADAPTER (CSD-1 ONLY)
USER'S MANUAL
"IGNITION MODULE HARNESS" (CSD-1 ONLY- ORANGE)
CONTROL COMPONENTS CARTON
CONTROL CENTER R8285D5001 WITH R8222U DPST RELAY
QTY PER MODEL
DAUGHTER BOARD MOUNTING BRACKET (CSD-1 ONLY)
KEY
DESCRIPTION
CROWN PART
#
16-325
16-390
16-455
16-520
16-585
*
OPTIONAL VENT DAMPER HARNESS
9605125
1
1
1
1
1
16-325
96-035
1
16-390
96-036
1
16-455
96-036
1
16-520
96-037
1
16-585
96-037
1
*
OPTIONAL AUTOMATIC VENT DAMPER
* NOT PICTURED
OPTIONAL AUTOMATIC VENT DAMPER KIT
KEY
DESCRIPTION
CROWN PART
#
QTY PER MODEL
Summary of Contents for 16 Series and
Page 2: ...2...
Page 4: ...4 2 II Specifications...
Page 12: ...12 10 Figure 6 Jacket Assembly...
Page 13: ...13 11 Figure 7 Gas Train Standard Build Figure 8 Gas Train CSD 1 Build 16 455 16 520 16 585...
Page 18: ...18 16 Figure 14 All Air From Outdoors Using Horizontal Ducts Into The Boiler Room...
Page 25: ...25 23 Figure 18 Standard Boiler Piping...
Page 26: ...26 Figure 19 Recommended Piping for Combination Heating Cooling Refrigeration System 24...
Page 30: ...30 28 Figure 21 Series 16 Standard Boiler Wiring...
Page 31: ...31 29 Figure 22 Series 16 CSD 1 Boiler Wiring...
Page 40: ...40 Figure 26 Exploded View Base Parts Manifold 38...
Page 42: ...42 Figure 27 Exploded View Base Heat Exchanger Flue Collector Assembly 40...
Page 44: ...44 42 Figure 28 Exploded View Jacket...
Page 46: ...46 44 Figure 29 Exploded View Trim Control Components...