6 = Control toggles
7 = Momentary control
8 = Control disables day zones
P502E
Misc partition options 2 - Default 3,4,6 1 = Key-switch enabled Page 27
2 = Use 2nd Key-switch
3 = Key-switch ARM's/STAY
4 = Pendant chirps when armed
5 = Pendant chirps when in Stay Mode
6 = 2 sec pulse at set
7 = 2 sec pulse at unset
8 = Access control even when armed
P503E PARTITION "C" TIME AND DELAY OPTIONS (Default 0)
Page 25
1 = set partition When Time Zone Ends
2 = Unset Partition When Time Zone Starts
3 = Disable Stay Mode Exit Delay
4 = Disable Set Mode Exit Delay
5 = Disable Stay Mode Entry Delay
6 = Disable Set Mode Entry Delay
7 = Use special Stay Mode entry timer
8 = Report Stay Mode alarms & Bypasses via dialer
System Delays & Timers
P511E
Zone 1 entry delay - Default 20 sec Delay timer values Page 34
P512E
Zone 2 entry delay - Default 20 sec 0 = instant, no delay Page 34
P513E
Zone 3 entry delay - Default 0 1-9999 = 1 -9999 seconds Page 34
P514E
Zone 4 entry delay - Default 0 Page 34
P515E
Zone 5 entry delay - Default 0 Page 34
P516E
Zone 6 entry delay - Default 0 Page 34
P517E
Zone 7 entry delay - Default 0 Page 34
P518E
Zone 8 entry delay - Default 0 Page 34
P519E
Zone 9 entry delay - Default 0
Page 34
P520E
Zone 10 entry delay - Default 0 Page 34
P521E
Zone 11 entry delay - Default 0 Page 34
P522E
Zone 12 entry delay - Default 0 Page 34
P523E
Zone 13 entry delay - Default 0 Page 34
P524E
Zone 14 entry delay - Default 0 Page 34
P525E
Zone 15 entry delay - Default 0 Page 34
P526E
Zone 16 entry delay - Default 0 Page 34
P531E
Area "A" exit delay - Default = 60 sec Page 34
P532E
Area "B" exit delay - Default = 60 sec Page 34
P533E
Area "C" exit delay - Default = 60 sec Page 34
P534E
Area "A" two trigger time period - Default 60 sec Page 34
P535E
Area "B" two trigger time period - Default 60 sec Page 34
P536E
Area "C" two trigger time period - Default 60 sec Page 34
P537E
Area "A" door open too long timer (DOTL) - Default 10 sec Page 36
P538E
Area "B" door open too long timer (DOTL) - Default 10 sec Page 36
P539E
Area "C" door open too long timer (DOTL) - Default 10 sec Page 36
P540E
Area "A" Special Stay Mode entry delay - Default 20 sec Page 34
P541E
Area "B" Special Stay Mode entry delay - Default 20 sec Page 34
P542E
Area "C" Special Stay Mode entry delay - Default 20 sec Page 34
P543E
Area "A" day zone keypad buzzer duration - Default 2 sec Page 35
P544E
Area "B" day zone keypad buzzer duration - Default 2 sec Page 35
P545E
Area "C" day zone keypad buzzer duration - Default 2 sec Page 35
P546E
Area "A" day zone to Output duration - Default 2 sec Page 35