Page 51
P428E Mains fail mapped to scenario 1-4 default 1
P429E Phone line restore mapped to scenario 1-4 default 1
P430E Radio PIR battery low mapped to scenario 1-4 default 1
P431E Radio-key battery low mapped to scenario 1-4 default 1
P432E Keypad tamper mapped to scenario 1-4 default 1
P433E Cabinet tamper mapped to scenario 1-4 default 1
P434E Radio panic mapped to scenario 1-4 default 1
P435E Test calls mapped to scenario 1-4 default 1
P436E Duress alarm mapped to scenario 1-4 default 1
P437E Supervised radio timeout mapped to scenario 1-4 default 1
P438E Zone inactivity timeout mapped to scenario 1-4 default 1
MULTIPLE ZONE REPORTING - P446E & P466E
P458E
1-8E Zone will report multiple activations for zones 1-8 (Default ON)
P478E
1-8E
Zone will report multiple activations for zones 9-16 (Default ON)
PROGRAMMING TEST CALL OPTIONS
- P815E - P816E
Because the Elite V6 runs a real time clock, it is possible to assign test calls by day of the week and time of day
rather than the more common practice of spacing test calls so many hours apart,.
P815E 0-7E
Test Call Days of the Week
- Where 1 = Sunday and 7 = Saturday. 0 = No Test
P816E XXXXE
Test Call Time of Day
- Where the time of the day you wish the panel to make its daily test
call is programmed in 24 hour format.
CONTACT ID CODE & SPEECH MESSAGE PROGRAMMING
CONTACT ID AREA ACCOUNT CODES
- P376E - P378E
P376E
XXXXE
Account Code for Area "A" Reports
- The Account code set at this address will be used to
report all system events Arms and Disarms, zone activations, restores and bypasses etc from
Area "A" - Default Account = 0000
P377E
XXXXE
Account Code for Area "B" Reports
- The account code set at this address will be used to
report Arms and Disarms, zone activations, restores and bypasses etc from Area "B"
P378E
XXXXE
Account Code for Area "C" Reports
- The account code set at this address will be used to
report Arms and Disarms, zone activations, restores and bypasses etc from Area "C"
ZONE CONTACT ID ALARM REPORTING CODE - P721E-P736E
P721E XXXE
Zone 1 Activation
Default = 130 0 = No Report
P722E XXXE
Zone 2 Activation
Default = 130
P723E XXXE
Zone 3 Activation
Default = 130
P724E XXXE
Zone 4 Activation
Default = 130
P725E XXXE
Zone 5 Activation
Default = 130
P726E XXXE
Zone 6 Activation
Default = 130
P727E XXXE
Zone 7 Activation
Default = 130
P728E XXXE
Zone 8 Activation
Default = 130
P729E XXXE
Zone 9 Activation
Default = 130
P730E XXXE Zone 10 Activation
Default = 130
P731E XXXE
Zone 11 Activation
Default = 130
P732E XXXE
Zone 12 Activation
Default = 130
P733E XXXE
Zone 13 Activation
Default = 130
P734E XXXE
Zone 14 Activation
Default = 130
P735E XXXE
Zone 15 Activation
Default = 130
P736E XXXE
Zone 16 Activation
Default = 130
Summary of Contents for Arrowhead Elite V6