Page 46
DIALLER PROGRAMMING
ENABLING DIALLER & SETTING DIALLING PARAMETERS - P370E
P370E 1-8E
System Options (Default = 7)
1 = Enable dialler
2 = Fax defeat
3 = Disable line monitoring
4 = DTMF or Pulse Dial
5 = Normal or Reverse Pulse Dial
6 = Spare
7 = Auto-Detect Modem Format
8 = Force Bell103/V21
Option 1
Enable Dialler
- This option is used to activate the dialler hardware. If this option is Off, all dialler
reporting activity will be disabled. - Default = Off
Option 2
Fax Defeat -
This option enables fax defeat mode. When enabled the panel will look for incoming
rings between 1-4 rings (inclusive). If the incoming call is then terminated the panel will answer
the next incoming call after one ring. If another call is not established within 45 sec of the first
call, the fax defeat mode is reset. For fax defeat to work the auto answer rings must be enabled
by putting in a suitable ring count (e.g. 25).
Option 3
Disable Line Monitoring
-If this option is enabled, then the panel no longer tests the telephone
line.
Option 4
DTMF or Pulse Dial -
Selects DTMF or Pulse dialling. Led Off = DTMF Dial.
Option 5
Normal or Reverse Pulse Dial
- With this option off, the dialling pulses are normal i.e. a 1 = 1
pulse, a 9 = 9 pulses. If the option is on, then the pulses are reversed i.e. a 1 = 9 pulses, a 9 = 1
pulse.
Option 6 Spare
Option 7
Auto-Detect Modem Format -
The panel can connect using Bell103 or V21 formats when
performing upload/download connections. If this option is On the panel generates the V21 tones
first and if no connection is established it then generates the Bell103 tones. If this option is turned
off then the format is fixed by the selection made at option 8.
Option 8
Force Bell103/V21 Modem Format -
If option 7 above is turned off then the modem format to be
used for upload/download is specified here. If this option is Off the format is Bell103, On is V21.
REPORTING SCENARIOS
-
P321E - P324E
P321E 1-16E
Reporting Scenario #1 options
(Default=1 7)
P322E 1-16E
Reporting Scenario #2 options
(Default = 0)
P323E 1-16E
Reporting Scenario #3 options
(Default = 0)
P324E 1-16E
Reporting Scenario #4 options
(Default = 0)
In order to provide you with the best flexibility when reporting alarms we have developed a unique system called
"Reporting Scenarios". The Scenarios define what action is taken by the panel for each alarm event, e.g. alternate
between numbers 1&2 until one is kissed-off or dual report to numbers 1&2 until both kissed-off. There are four
individual scenarios available each with up to 16 possible steps. The Scenarios consist of a string of digits that define
the reporting action to be taken by the panel. The digits in a Scenario are pre-defined. What the various digits are
and their meaning are listed below.
Scenario Options;
1 = Call Telephone Number 1 6 = Call Telephone Number 6
2 = Call Telephone Number 2 7 = Return to step 1 until all numbers are kissed-off
3 = Call Telephone Number 3 8 = Return to previous step if not kissed-off
4 = Call Telephone Number 4 9 = Stop if kissed-off, if not proceed to next step
5 = Call Telephone Number 5
Example 1 (alternate dialling)
1 9 2 9 7
In this example we have defined a scenario with five steps as follows.
Summary of Contents for Arrowhead Elite V6