Page 34
P476E 1-8E
Access Control door position input
- Where options 1-8 represent zones 9-16 respectively.
The door position input becomes a 24 hour alarm zone and will alarm if the “Control” door is
forced open or left open too long. It will also automatically re-lock the door after the “Control”
operation has occurred and the door has been opened then closed again. (Default none)
P477E 1-8E
Access Control Request to exit input
- Where options 1-8 represent zones 9-16 respectively.
The Request to Exit input will operate the “Control” door output to release the door and start the
Door open Too long Timer. (Default none)
P478E 1-8E
Zone will report multiple activations via dialler
- Where options 1-8 represent zones 9-16
respectively. If this option is turned off then the relevant zone will only report one alarm to a
monitoring company during any single armed period. If it is turned on, the zone can send multiple
reports if activated more than once during a single armed period.
P479E 1-8E
Zone will be Monitored for Inactivity
- Where options 1-8 represent zones 9-16 respectively. A
Zone with this option turned on will be checked to ensure that it is triggered on a regular basis. If
the zone is not triggered within the time period set at P569E then an alarm will be generated as
the detector may have become faulty or could be masked.
The timer period as set at address
P569E is only active during the disarmed period. If the timer has started due to inactivity of a zone
input, the elapsed time is remembered at the time of arming and will resume when the alarm is
disarmed.
P480E 1-8E
Can Arm if Zone is Unsealed
- Where options 1-8 represent zones 9-16 respectively. Default
None. If a zone is unsealed (Not Ready) at the time of arming, by default the panel will Arm and
the zone will be automatically bypassed at the end of the exit delay. If option #1 at P301,P401 or
P501 is on then the panel will not Arm if a zone in that area is unsealed. If this option is set for any
zone then the panel will ignore an unsealed condition on the selected zone/s and allow arming to
happen.
PROGRAMMING DELAYS & TIMERS
ZONE ENTRY DELAY TIMES
- P511E to P516E
P511E 0-9999E
Zone 1 entry delay
- 0-9999 seconds - default 20 seconds
P512E 0-9999E
Zone 2 entry delay
- 0-9999 seconds - default 20 seconds
P513E 0-9999E
Zone 3 entry delay
- 0-9999 seconds - default 0 (Instant)
P514E 0-9999E
Zone 4 entry delay
- 0-9999 seconds - default 0 (Instant)
P515E 0-9999E
Zone 5 entry delay
- 0-9999 seconds - default 0 (Instant)
P516E 0-9999E
Zone 6 entry delay
- 0-9999 seconds - default 0 (Instant)
P517E 0-9999E
Zone 7 entry delay
- 0-9999 seconds - default 0 (Instant)
P518E 0-9999E
Zone 8 entry delay
- 0-9999 seconds - default 0 (Instant)
P519E 0-9999E
Zone 9 entry delay
- 0-9999 seconds - default 0 (Instant)
P520E 0-9999E
Zone 10 entry delay
- 0-9999 seconds - default 0 (Instant)
P521E 0-9999E
Zone 11 entry delay
- 0-9999 seconds - default 0 (Instant)
P522E 0-9999E
Zone 12 entry delay
- 0-9999 seconds - default 0 (Instant)
P523E 0-9999E
Zone 13 entry delay
- 0-9999 seconds - default 0 (Instant)
P524E 0-9999E
Zone 14 entry delay
- 0-9999 seconds - default 0 (Instant)
P525E 0-9999E
Zone 15 entry delay
- 0-9999 seconds - default 0 (Instant)
P526E 0-9999E
Zone 16 entry delay
- 0-9999 seconds - default 0 (Instant)
AREA EXIT DELAY TIMES
- P531E to P533E
P531E 0-999E
Area "A" exit delay
- 0-999 seconds - Default 60 seconds
P532E 0-999E
Area "B" exit delay
- 0-999 seconds - Default 60 seconds
P533E 0-999E
Area "C" exit delay
- 0-999 seconds - Default 60 seconds
TWO TRIGGER TIMERS
- P534E to P536E
P534E 0-999E
Area "A" Two Trigger time period
- Default 60 seconds
P535E 0-999E
Area "B" Two Trigger time period
- Default 60 seconds
P536E 0-999E
Area "C" Two Trigger time period
- Default 60 seconds
STAY MODE ENTRY DELAY TIMES
- P540E to P542E
120 sec 2 min
180 sec 3 min
240 sec 4 min
300 sec 5 min
360 sec 6 min
420 sec 7 min
480 sec 8min
540 sec 9 min
600 sec 10min