Page 38
4E = Radio user #1 will arm
5E = Radio user #1 will disarm
6E = Radio user #1 can Arm Stay Mode on
7E = Radio user #1 can Disarm Stay Mode off
8E = Radio user #1 is disabled during alarm state
Option 1 Radio user #1 is assigned to Area "A"
- The functions set by options 4-7 will be active in Area "A"
Option 2 Radio user #1 is assigned to Area "B"
- The functions set by options 4-7 will be active in Area "B"
Option 3 Radio user #1 is assigned to Area "C"
- The functions set by options 4-7 will be active in Area "C"
Option 4 Radio user #1 will arm
- When this option is enabled, radio user #1 will arm whichever area is
assigned by options 1-3
Option 5 Radio user #1 will disarm
- When this option is enabled, radio user #1 will disarm whichever area
is assigned by options 1-3
Option 6 Radio user #1 can Arm Stay Mode
- When this option is enabled, radio user #1 will turn Stay
Mode on in whichever area is assigned by options 1-3
Option 7 Radio user #1 can Disarm Stay Mode
- When this option is enabled, radio user #1 will turn Stay
Mode off in whichever area is assigned by options 1-3
Option 8 Radio user #1 is disabled during alarm state
- When this option is enabled, radio user #1 can
not be used to reset an alarm, i.e. it must be reset at the keypad.
Where P661E sets options for radio user #1, P662 sets options for radio user #2 etc
P661E Radio user #1 options P671E Radio user #11 options
P662E Radio user #2 options P672E Radio user #12 options
P663E Radio user #3 options P673E Radio user #13 options
P664E Radio user #4 options P674E Radio user #14 options
P665E Radio user #5 options P675E Radio user #15 options
P666E Radio user #6 options P676E Radio user #16 options
P667E Radio user #7 options P677E Radio user #17 options
P668E Radio user #8 options P678E Radio user #18 options
P669E Radio user #9 options P679E Radio user #19 options
P670E Radio user #10 options P680E Radio user #20 options
ASSIGNING OUTPUT & PANIC OPTIONS TO RADIO KEYS
-
P681E - P700E
P681E 1E
=
Radio user #1 turns control function on
2E = Radio user #1 turns control function off (Toggles if 1 on)
3E = Radio user #1 turns output on
4E = Radio user #1 turns output off (Toggles if 3 ON)
5E = Radio user #1 is instant panic
6E = Radio user #1 is delayed panic (1.5 sec)
7E = Spare
8E = Spare
Option 1 Radio user #1 turns control function on
- When this option is enabled, the radio user will turn
on the Control Function as if it were operated from the keypad.
Option 2 Radio user #1 turns control function off
- When this option is enabled, the radio user will turn
the control output off as if it were operated from the keypad. (Dependant on control options)
Option 3 Radio user #1 turns output on
- When this option is enabled, the radio user will turn on the
output as assigned by P581E.
Option 4 Radio user #1 turns output off
- When this option is enabled, the radio user will turn off the
output as assigned by P581E. This function is only valid when there is no reset time assigned to
the output in question.
Summary of Contents for Arrowhead Elite V6