Page 22
PROGRAMMING KEYPAD OPTIONS
KEYPAD OPTIONS
- P250E - P278E
The block of addresses from P250E to P278E are used to assign the basic options of each keypad in the system.
Each of the addresses from P250E to P278E may have 8 options assigned where the 8 options represent the
programmed keypad number. i.e. if options 1, 2 & 4 are enabled at address P250E then keypads 1, 2 and 4 would be
assigned to area "A".
NOTE: A keypad can only be used to control the partition or area to which it has been assigned.
Within the display of the Elite V6 keypads you will find the indicators "
A
", "
B
" and
“C”.
These indicators are used to
show the Armed state of individual areas (LED on) or whether an area is in Stay Mode (LED flashing).
P250E 1-8E
Keypads assigned to Area A
(Default 1-8)
If the LED is On, the keypad is assigned to Area A.
P251E 1-8E
Keypads assigned to Area B
(Default none)
If the LED is On, the keypad is assigned to Area B.
P252E 1-8E
Keypads assigned to Area C
(Default none)
If the LED is On, the keypad is assigned to Area C.
P253E 1-8E
Keypads with permission to fully Arm
(Default 1-8)
If the LED is On, the keypad is allowed to Arm the assigned Area/s.
P254E 1-8E
Keypads with permission to arm Stay Mode
(Default 1-8)
If the LED is On, the keypad is allowed to Arm Stay Mode for the assigned Area/s.
P255E 1-8E
Keypads with permission to use the Control Function
(Default 1-8)
If the LED is On, the keypad can operate the “Control” function for the assigned Area/s.
P256E 1-8E
Keypads with permission to Bypass
(Default 1-8)
If the LED is On, the “Bypass” button on the keypad is enabled.
P257E 1-8E
Keypads with Panic button enabled
(Default 1-8)
If the LED is On, the “Panic” button on LED keypads is enabled and is instant.
P258E 1-8E
Keypads with delayed Panic button enabled
(Default 1-8)
If the LED is On, the “Panic” button on LED keypads must be held down for 2 seconds to create
a panic alarm. The option at address P257E MUST be off for the delayed option to work.
P259E 1-8E
Keypads with Buttons 1 & 3 Panic Alarm enabled
(Default 1-8)
If the LED is On, pressing buttons 1&3 simultaneously will create a Panic alarm at the keypad.
P260E 1-8E
Keypads with Buttons 4 & 6 Fire Alarm enabled
(Default 1-8)
If the LED is On, pressing buttons 4&6 simultaneously will create a Fire alarm at the keypad
P261E 1-8E
Keypads with Buttons 7 & 9 Medical Alarm enabled
(Default 1-8)
If the LED is On, pressing buttons 7&9 simultaneously will create a Medical alarm at the
keypad
P262E 1-8E Keypads with buzzer mapped to normal zone alarms
(Default 1-8)
If the LED is On, a Zone alarm during the Armed state will cause the Keypad buzzer to sound
(audible alarm) at the keypad.
P263E 1-8E Keypads with buzzer mapped to stay mode zone alarms
(Default 1-8)
If the LED is On, a Stay Mode Zone alarm during the Armed state will cause the Keypad buzzer
to sound (audible alarm) at the keypad.