Page 17
e.g. To reset User Codes 1-50 (P 840E)
Press <
PROGRAM
> - 840 - <
ENTER
>
3 beeps - Program light flashing
After resetting the various defaults, all options associated with that function (eg User Code Defaults P840E) will be
set to the default values shown in the Program Summary at the rear of this manual. The default settings have been
chosen to simplify the installation process by minimising the amount of programming necessary to get the system
fully functional.
TO EXIT PROGRAM MODES
To exit program modes when you have finished programming:
Press <
PROGRAM
> - <
ENTER
>
Program light goes out
The panel is now back in normal Run Mode, any program changes you have made will have replaced previous
values and be in effect.
Note:
During programming Tampers and 24 hour alarms are disabled which allows quiet access to the panel,
detectors and satellite siren units etc. On exiting program mode, all inputs are scanned and if any tampers or 24Hr
alarms are present an activation will occur.
Note: Where there are multiple options at one address, the numbers “0” & “9” have been reserved. Entering
a “0” at the address will turn all options OFF at that address whereas entering a “9” will turn all options ON
at that address.
USER CODE PROGRAMMING
USER CODES
- (P1E to P50E) &
INSTALLER CODE -
(P249E)
There are 51 codes available in the Elite, 50 user codes and 1 installer code. The user codes are located at
addresses 1-50. By default,
Code 1 is the Master Code
because it has full access to enter program mode. Other
user codes can be programmed as master codes also if required. The Installer code is stored at address 249 and is
used to move from
Client
Program mode up to
Installer
Program mode.
Codes 1-50 may be varied in length from 1 to 6 digits. Code 249 must be 3-6 digits.
To program a User Code you must first be in client or installer program mode
, then select the address from 1-
50. (If there is already a code programmed at this address, it will be flashed back to you)
NOTE: Not all User Codes may have the ability to access Client Program Mode. The installer can restrict access to
Users so that they have no access to Client Mode or they can have access to change only their code or they may
have access to change all User codes as defined at addresses P101-P150.
To change User code 1 from the default setting of 1,2,3 to 9,8,7,6 you would enter the following data at the keypad.
P 1 E
(
Old code is flashed back at the keypad, in this case it will be 1,2,3)
Then
9876 E
3 beeps - program light On or Flashing
The new code will now be displayed back using the keypad LED’s
To program a new user code for User 5 you would enter the following;
P 5 E
(
If a code was there it would be displayed if not the display will be blank )
Then
567 E
3 beeps - program light On or Flashing
The new code will now be displayed back using the keypad LED’s
To replace a code simply enter the new code in the same address as the old code. This will overwrite the previous
code but maintain the user permissions as mapped to that user number.