Merchant™ Operators’ Guide
Program-
1810006
65
January 2008
Homing the Motors - Motor Status Detail
1. Press
until you reach the
Main
Menu
, then use
or
to select
Test,
and press
.
2. In the
Test
menu, use
or
to select
Motor Status Detail
and
press .
3. In the
Motor Status Detail
menu, select
the tray where the product spiral with the
motor needing homing is located.
NOTE
In the
Tray X
menu, the product spirals with
homed motors will be indicated with an “
H
” in
the line adjacent to the spiral number(s.)
4. In the
Tray X
menu, select the product
spiral number where the motor needing
homing is located.
+
_
+
_
Main Menu
Data Recall
5
Diagnostic
Test
Price
Product Configuration
6
Press EDIT to Select
Test
Test Vend
5
Test Vend w/o SureVend
SureVend Detectors
Motor Test Summary
Motor Status Detail
6
Press EDIT to Select
Motor Status Detail
Tray 1
5
Tray 2
Tray 3
Tray 4
Tray 5
6
Press EDIT to Select
Tray 3
301 – H – – – – – – –
5
302 – H – – – – – – –
303 – – – – – – – – –
304 – H – – – – – – –
305 – H – – – – – – –
6
Press EDIT to Select
Summary of Contents for Merchant 180
Page 1: ...EXIT ...
Page 9: ...Merchant Operators Guide Initial Setup 1810006 1 January 2008 FRONT EXTERIOR VIEWS ...
Page 11: ...Merchant Operators Guide Initial Setup 1810006 3 January 2008 MODELS 180 181 MONETARY ...
Page 12: ...Initial Setup Merchant Operators Guide January 2008 4 1810006 INTERIOR VIEW ...
Page 170: ...Index Merchant Operators Guide January 2008 Index 6 1810006 ...