7.4
Specific maintenance operations
If the standard inspection and maintenance operations have revealed
the necessity to carry out additional maintenance work, proceed as
follows, depending on the nature of the work:
7.4.1.
Inspection of the ignition electrode
1. Remove the ignition electrode plug from the ignition transformer.
The ignition cable is fixed to the ignition electrode and
therefore may not be removed.
2. Unscrew the 2 screws. Remove the unit.
3. Wipe off all traces of deposits using an abrasive cloth.
4. Check the ignition electrode for wear. Replace if necessary.
5. Check the gasket.
6. Refit all parts, replacing those that are damaged.
T002872-A
4
1
2
3
Quinta Pro 30 - 45 - 65 - 90 - 115
7. Checking and maintenance
250413 - 123157-03