13. Relay PCB Replacement
Disconnect power supply to the
FX134A / FX1234 / FX3030
series.
Danger:
Only a qualified service technician should service this equipment. An Electrical Shock hazard is present which
could lead to severe injury or even death.
a. Service Access: Please see Section 1 part 2 & 3
b. Locate Relay PCB in vacuum pump compartment.
c. Disconnect wires and remove PCB using needle nose pliers on standoffs.
Relay PCB location
Relay PCB
To remove PCB from stand offs. Squeeze stand off from
flat side using a pair of needle nose pliers to depress little
clip and slide PCB corner off of stand off.