41
11. LO and HI Manifold Replacement
Disconnect power supply to the
FX134A / FX1234 / FX3030
series.
Danger:
Only a qualified service technician should service this equipment. An Electrical Shock hazard is present which
could lead to severe injury or even death.
Danger- Avoid breathing refrigerant vapors and lubricant vapor or mist. Breathing high concentration levels may
cause heart arrhythmia, loss of consciousness, or even cause suffocation.
Caution- all hoses may contain liquid refrigerant under pressure. Contact with refrigerant may cause frostbite or other
related injuries. Wear proper personal protective equipment such as safety goggles and gloves. When disconnecting any
hose, please use extreme caution.
Caution- avoid breathing refrigerant vapors and/or lubricant mist. Exposure may irritate eyes, nose, throat, and skin.
Please read the manufacturers Material Safety Data Sheet for further safety information on refrigerants and
lubricants.
Danger: Always assume that high-pressure refrigerant exists. Failure to do so may result in bodily injury.
a. Recover any refrigerant in service hoses.
b. Close both tank valves and ball valves on tank hoses.
c. Remove tank hoses from purge block to release any remaining pressure.
d. Front Panel Service Access: Please see Section 1 part 2 to service internal hoses.
e. Locate lo or hi manifold block.
f. Disconnect refrigerant hoses and wire connections.
g. Remove the two mounting bolts located on aluminum body.
Lo Block
Hi Block
Mounting bolts
Mounting bolts
Summary of Contents for FX1234
Page 1: ...1 FX Series Service Manual Models FX134 FX1234 FX3030 CPS AUTOMOTIVE RECOVER RECYCLE RECHARGE ...
Page 14: ...14 FX3030 PUMP DOWN ...
Page 15: ...15 Hose Flush High Voltage Compressor ...
Page 47: ...47 1 FX134A FX1234 FX3030 Series Refrigeration Schematic ...
Page 48: ...48 2 FX134A FX1234 FX3030 Series Electrical Schematic ...