20
4. Scale/PCB Board Recalibration Procedure
a.
Remove back tank cover by removing both thumb screws holding cover on to main chassis.
b.
Remove tank strap from tank, and unplug heater blanket. Then turn both ball valves on tank hoses to the off position, and
disconnect tank hoses from purge block. Then remove tank from scale platform and place to the side.
c.
Turn unit on and allow main screen to come up. Select the gears icon at the bottom of screen. Then select the wrenches
icon on next screen. Then select the scale icon on next screen. Then select the scale icon with plus sigh on scale on next
screen. Enter password
ABBA1216
to allow full calibration. Follow instruction on screen to complete calibration.
Replace tank and tank strap around tank. Don’t forget to plug heater blanket backing before installing tank cover.
Note:
25lb weight is needed.
Remove Thumbs screw both sides
Remove tank strap
Unplug heater blanket
Remove tank hoses