12
AIR PURGE
Air Purge is performed automatically on the FX134A / FX 1234 / FX3030 series. Two thermistors are used to determine if the
storage tank have had enough time to stabilize. Once it is determine Air Purge can take place, the unit will open the charging
solenoid valve (LS1) to the Pressure transducer (PT). The PT compares this pressure to the actual saturated pressures stored in
the PCB microprocessor. If Air Purge is required, the Air Purge solenoid pressure.