I
NTRODUCTION
D
OC
.01040043
R
EV
.6
1-9
The main RF voltage will be supplied using all available modules to a maximum of four total.
The extra power supplies are hot swappable (able to be changed while the unit is operating). At
least one module is required to operate the amplifier. The operator can observe the status of the
power supply using the front panel display, which will update with each module
insertion/extraction. Table 1-3 provides a list of parts provided for each configuration of
redundant power supply.
Table 1-3. Redundant Power Supply Parts and Quantity Supplied
Parts List
N+0 (Qty)
N+1 (Qty)
N+2 (Qty)
N+3 (Qty)
Screw 10-32 x ½
1290050100
4 4 4 4
Connector Lock and Entry
5350002870
1 2 3 4
Power Supply Module
7850111370
1 2 3 4
Power Supply Rack
7850111770
1 1 1 1
Blank Panel
7850111800
3 2 1 0
DC Power Harness
0104466500
1 1 1 1
Redundancy Alarm Harness
0104466700
1 1 1 1
Note: Do not disconnect the DC Power Harness on the Power Supply Rack.
Reversing the polarity while reconnecting the DC Power Harness will cause
permanent damage and void the warranty.
Note: Do not remove all redundant power supplies while Indoor SSPA is in
operation.
1.4.5
Transient Surge Suppression
The transient surge suppression module allows the SSPA to handle 6KV surges without
effecting operation. The TVSS module is rated for 10,000 Amps and 300 Joules. This option
allows the amplifier to be compliant with EN61000-4-5, 6kV voltage surges: both common mode
and differential mode power line voltage surges.
Summary of Contents for S4UIA
Page 4: ...INDOOR SSPA IV DOC 01040042 REV 6 This page is intentionally left blank...
Page 23: ...UNPACKING INSTALLATION DOC 01040044 REV 6 2 7 Figure 2 1 Connector Locations C band shown...
Page 42: ...INITIAL POWER ON CHECKOUT 4 10 DOC 01040053 REV 6 This page is intentionally left blank...
Page 66: ...OPERATION 5 24 DOC 01040086 REV 7 This page is intentionally left blank...
Page 80: ...SSPA FUNCTIONAL TREE 7 2 DOC 01040089 REV 4 This page is intentionally left blank...
Page 90: ...CUSTOMER WARRANTY AND SUPPORT A 2 APP 01040025 REV 1 This page is intentionally left blank...