40
ELECTRICAL HOOK-UP
INSTALLATION MANUAL
ELECTRICAL
HOOK-UP
Avoiding the risk of electrocution
CAUTION
All electrical work should be done by a qualified
electrician, otherwise the certification and
warranty will be voided. Furthermore, any
modifications to the electrical components will
also void the warranty.
ELECTRICAL DANGER
Failure to comply with these instructions may
result in death by electrocution or serious injury.
Disconnect or turn off and secure all power
supplies before starting an intervention on the
COVANA cover.
For AC-operated model
: A disconnect mean
needs to be incorporated into the fixed wiring at
the time of installation. This mean must be
accessible to the user or service technician to turn
the power off for future maintenance or repair.
Always have a licensed electrical contractor
perform any electrical maintenance or repairs on
the COVANA cover. The wiring must comply with
all applicable local electrical codes and
regulations.
The COVANA operator must be connected to a
circuit that is protected by a dedicated GFCI that
complies with all applicable local electrical codes
and regulations.
Install the COVANA cover in such a way that
drainage directs water away from the electrical
components.
Do not connect any auxiliary components to the
electrical system of the COVANA cover unless
they have been approved by COVANA.
Replace electrical components with original
components provided or approved by COVANA.
Ask your dealer for replacement parts.
ELECTRICAL WARNING
To reduce the risk of electric shock, the green-
colored terminal or the terminal marked
“g,” “gr,”
“ground,” “grounding” or with the
⏚
symbol that is
located inside the supply terminal box or
compartment must be connected to the
grounding mean provided in the electric supply
service panel with a continuous copper wire
equivalent in size to the circuit conductors
supplying the equipment.
Two
lugs marked “bonding lugs” are provided on
the external surface or on the inside of the supply
terminal box or compartment. To reduce the risk
of electric shock, connect the local common
bonding grid in the area of the COVANA cover.
Use terminals with an insulated or bare copper
conductor no smaller than No. 6 AWG (13.30
mm
2
).
ELECTRICAL CAUTION
All field-installed metal components, such as
rails, ladders, drains or other similar hardware,
within 10 ft (3 m) of the hot tub must be bonded
to the equipment grounding bus with copper
conductors no smaller than No. 6 AWG (13.30
mm
2
).
Summary of Contents for OASIS
Page 1: ...2019 Revision 0 2019 04 03 C A 232859 ...
Page 44: ...44 TECHNICAL SPECIFICATIONS INSTALLATION MANUAL NOT TO SCALE Long side LS model Figure 87 ...
Page 49: ...INSTALLATION MANUAL APPENDIX 49 APPENDIX ...
Page 50: ...50 APPENDIX INSTALLATION MANUAL ...
Page 51: ...INSTALLATION MANUAL APPENDIX 51 ...
Page 52: ...52 APPENDIX INSTALLATION MANUAL ...
Page 53: ...INSTALLATION MANUAL APPENDIX 53 ...
Page 54: ...54 APPENDIX INSTALLATION MANUAL ...
Page 55: ...INSTALLATION MANUAL APPENDIX 55 ...
Page 56: ...56 APPENDIX INSTALLATION MANUAL ...
Page 57: ...INSTALLATION MANUAL APPENDIX 57 ...
Page 58: ...58 INSTALLATION MANUAL This page intentionally left blank see next page ...