Applications manual
For AME series
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
R
︓
Read command
W
︓
Write command
:Returning a status of the PG alarm.
R
READ_LV_ALARM
:Returning a status of the LV alarm.
R
READ_PG_ALARM
TOTAL_OUTPUT_TIME_2
:Returning an accumulated operation time. (low 16 bits of hour)
R
:Returning an accumulated operation time. (minute)
R
TOTAL_INPUT_TIME_1
:Returning an accumulated time that the input voltage has been
applied. (minute)
R
TOTAL_INPUT_TIME_2
:Returning an accumulated time that the input voltage has been
applied. (low 16 bits of hour)
R
TOTAL_OUTPUT_TIME_3
:Returning an accumulated operation time. (high 16 bits of
hour)
R
TOTAL_INPUT_TIME_3
Table 6.1 Command outline (4/4)
6.8 State acquisition commands
READ_STOP_CODE
:Returning the code representing the halt condition.
R
:Returning an accumulated time that the input voltage has been
applied. (high 16 bits of hour)
R
TOTAL_OUTPUT_TIME_1
SYS_STORE_USER_SETTING
:Storing settings into the internal non-volatile memory.
W
6.9 Commands to set address, memory, and communication
SET_WRITE_PROTECT_ON
:Enabling a protection for the Write command.
W
SET_WRITE_PROTECT_OFF
:Disabling a protection for the Write command.
W
READ_SELECTION_CH
:Returning the selected slot for setting.
R
SET_SELECTION_CH
:Setting a selected slot.
W
READ_WRITE_PROTECT_PRM
:Returning a status of the protection for the Write command.
R
CTL_ACCUMULATE_MODE_OFF
:Disabling the accumulation mode.
W
READ_ACCUMULATE_MODE
:Returning a setting status of the accumulation mode.
R
SYS_RESTORE_FACTORY_SETTING
:Restoring a factory default for settings.
W
CTL_ACCUMULATE_MODE_ON
:Enabling the accumulation mode.
W
READ_STORE_USER_SETTING
:Returning a status of the stored setting in the internal non-
volatile memory.
R
SET_ADDRESS
:Setting a communication address.
W
READ_ADDRESS_PRM
:Returning a setting value of the communication address.
R
CTL_ACCUMULATE_EXEC
:Execution command in the accumulation mode.
W
CTL_ACCUMULATE_CLEAR
:Erasing buffer in the accumulation mode.
W
:Returning the lower four digits of the product lot number.
R
READ_ADDRESS
:Returning a communication address.
R
6.10 Commands to acquire product information
READ_SERIAL
:Returning the product serial number.
R
READ_IOUT_POINT
:Returning the decimal point position of the return value from
MON_IOUT command.
R
READ_VOUT_POINT
:Returning the decimal point position of the return value from
MON_VOUT command.
R
READ_RATED_VOUT
:Returning the rated voltage of the model.
R
READ_RATED_IOUT
:Returning the rated current of the model.
R
READ_VIN_POINT
:Returning the decimal point position of the return value from
MON_VIN command.
R
READ_PRODUCT_INFO
:Returning a information of output module.
R
READ_LOT_H
:Returning the upper three digits of the product lot number.
R
READ_LOT_L
READ_PR_ALARM
:Returning a status of the PR alarm.
R
14
ver1.1E 2020.2.12