6.9 Commands to set address, memory, and communication
6.9.1
SET_SELECTION_CH [1Ah] [1Ch] [Argument]
Example:
The command corresponding to this command is shown below.
READ_REMOTE_PRM
READ_REMOTE_CONTROL
Commands to set constant current
Commands to set output voltage sequence
SET_TOFF_DELAY_SLOT
:Set stop delay time from output OFF
Commands to set accessory functions
READ_VOUT_LV_ALARM_PRM
TOTAL_OUTPUT_TIME
:Returns the cumulative output time
READ_STOP_CODE
:Returns the code indicating the cause of the stop
READ_LV_ALARM
:Returns the LV alarm status
State acquisition commands
Monitor commands
MON_VOUT
:Returns the output voltage
:Returns the set value of the startup delay time from output ON
READ_TOFF_DELAY_SLOT_PRM
:Returns the set value of stop delay time from output OFF
SET_RAMP_RATE
:Select the output voltage change rate
MON_IOUT
:Returns the output current
MON_OUTPUT_POWER
:Returns the output power
SET_VOUT_HV_ALARM
:Set the voltage to output an alarm signal when the output voltage rises
READ_VOUT_HV_ALARM_PRM
:Returns the voltage at which an alarm signal is output when the output voltage rises
SET_VOUT_ALARM_FACTORY_SETTING
:Return the output voltage to output the alarm signal to the factory default
By selecting the input module or target slot with this command and sending the corresponding
command, it is possible to set the selected target and return the setting status.
The factory default is the front-end module.
The following symbol mark is displayed on commands that assume input of this command.
SET_SELECTION_CH Corresponding commands
Commands to turn output voltage on/off
CTL_REMOTE_ON_CH
:Turn ON the output voltage
CTL_REMOTE_OFF_CH
:Turn OFF the output voltage
(All commands)
:Send command to selection
SET_TON_DELAY_SLOT
:Set the startup delay time from output ON
:Returns the output ON / OFF setting status by communication
:Returns the output ON / OFF setting status
Commands to set output voltage
(All commands)
:Send command to selection
:Returns the voltage at which an alarm signal is output when the output voltage drops
READ_RAMP_RATE_PRM
:Returns the rate of change of output voltage
SET_VOUT_LV_ALARM
:Sets the voltage to output an alarm signal when the output voltage drops
READ_TON_DELAY_SLOT_PRM
Applications manual
For AME series
41