Applications manual
For AME series
6.2.14
SET_GI_TERMINAL_MODE_GI [1Eh] [09h] [0Eh] [02h]
This command sets the GI2 terminal to work for GI function.
This is the factory default.
6.2.15
SET_GI_TERMINAL_MODE_RC [1Eh] [09h] [0Eh] [03h]
This command sets the GI2 terminal to work for the remote on/off function.
The active PFC and built-in fans do not stop by the remote on/off function.
6.2.16
READ_GI_TERMINAL_MODE_PRM [1Eh] [09h] [1Eh] [06h]
This command returns a setting of the GI2 terminal.
Return value:0
=>
Global inhibit function
Return value:1
=>
Remote control function
6.2.17
CTL_RESET_LATCH [1Eh] [08h] [1Eh] [1Fh]
After this command is transmitted, only outputs in all slots can be inhibited by supplying the current
to the GI2 terminal.
This command deactivates the latch that have been activated by OVP, etc. Latches on all outputs are
deactivated.
Transmit this after solving all abnormal conditions.
Return value
0
Return value
1
Status
After this command is transmitted, outputs can be inhibited as the "GI" state by supplying the current
to the GI2 terminal.
Return value
0
19