6.5.4
SET_TOFF_DELAY_SLOT [10h] [
Argument
]
0 - 3000
Argument:900 => 900 msec
Argument value
No delay time is set for the RC terminal of each output module.
If the front-end module is target, an error is returned.
(Error code 6 : Command that do not correspond to the setting target)
6.5.5
READ_TOFF_DELAY_SLOT_PRM [1Eh] [09h] [1Dh] [07h]
If the front-end module is target, an error is returned.
(Error code 6 : Command that do not correspond to the setting target)
6.5.6
SET_TOFF_DELAY_FACTORY_SETTING [1Eh] [09h] [0Dh] [01h]
0
Return value
The setting by this command causes a delay due to the processing time of the slave which is the AME
series.
The factory default is "0".
This command restores the delay time to power-off set by "SET_TOFF_DELAY_SLOT" command
for all slots to the factory default.
Return value
The delay time to power-off that has been stored in the non-volatile memory by
"SYS_STORE_USER_SETTING" command does not change.
No delay time is set under conditions which the power conversion cannot be maintained like the
lower input voltage than the stop voltage.
Example of argument
This command returns the value (the argument value) set by
"SET_TOFF_DELAY_SLOT" command.
This command sets the value of the delay time, in ms, from when a stop signal which is
the GI or the communication signal of the module inhibit is received to when power
conversion stops. (See Figure 6.5.2.)
*The power conversion stops after delay time set by
"SET_TOFF_DELAY_SLOT" command, when meeting the stop-condition by
the GI or communication remote on/off.
Figure 6.5.2 Timing diagram of "SET_TOFF_DELAY_SLOT"
Settable range
SET_TOFF_DELAY_SLOT
Vin
GI
(Com. remote on/off)
Vout
output ON
output OFF
27