RMU1 Separate DC and AC Coupons
DC
CP Coupon
Structure
Reference
Cell
DATA
SLOT
DESCRIPTION
1
Coupon DC Potential
2
3
4
Coupon AC Potential
Coupon Instant Disconnect DC Potential
Coupon AC Current Density
5
6
Coupon DC Protection Current
Depolarized Coupon DC Potential
LCD ICONS
COUPON DC V
COUPON AC V
COUPON INSTANT DISCONNECT DC V
COUPON CURRENT AC A/m2
COUPON CURRENT DC A/m2
COUPON DEPOLARIZED DC V
AC
CP Coupon
Separate DC and AC
Coupon Adapter
Assembly
Figure 12 Separate DC and AC Coupons Wiring Diagram (CP38)
When using separate DC and AC coupons with the RMU1, an adapter board must be used. This adapter board contains
a precision shunt resistor and provides a terminal block for connections to the coupons, structure and reference cell. The
shunt is a 10 ohm resistor; this shunt resistance must be used in the coupon calculator in the RMU1 configuration
application to obtain correct readings.