MOBILTEX® DATA LTD.
Calgary, Alberta
www.corTalk.com
TITLE:
RMU1 Installation and Configuration Guide
DOCUMENT NO.:
RMU1-MAN-001
SHEET:
33 of 53
REV:
1.14
6
Configuration Using a PC
6.1 Configuration Equipment Requirements
The following items will be needed when configuring an RMU1.
1.
RMU1 Programming Interface (A15000RMU1P or A20A0332701) or RMU1/2/3 Programming Interface with
RMU1ADP (Kit A20A0333101)
The RMU1 programming interface is shown in Figure 28. It has one cable exiting, a USB cable that attaches
to a PC. The interface is powered from the PC USB port, so an external power supply in not required. USB
cable color may be either white (A15000RMU1P) or black (A20A0332701).
The RMU1/2/3 programming interface and RMU1ADP adapter are shown in Figure 29. The RMU1ADP cable
is plugged into circular connector on the RMU1/2/3 programming interface labelled ‘TO RMU1/2/3 BASE”.
The interface is powered from the PC USB port, so an external power supply in not required.
2.
Programming Application and Driver CD or USB Key
To use the programming interface, you will require the CD or USB key that shipped with the programming
interface box. The CD contains drivers and an application for the RMU1 programming interface. If you do
not have the media, the contents can be downloaded from the Mobiltex support site. Contact your Mobiltex
representative for download instructions.
3.
Personal Computer (PC)
The application software and drivers require that the PC be running Windows 7 or higher for an operating
system. The PC must have an available USB port.
Figure 28 RMU1 Programming Interface
Figure 29 RMU1/2/3 Programmer With RMU1ADP