Malfunctions in operation of the impressed-current anode system CORREX
®
UP 2.3-919 are normally indicated by a rre
ed
d fflla
as
sh
hiin
ng
g L
LE
ED
D in the potentiostat
housing.
N
No
otte
e:: Many faults can be located and rectified directly on the system by mea-
suring DC voltage and current, polarity, insulation and resistance. The neces-
sary measuring techniques are described in chapter 9.2. Disconnect any
installed electrical tubular heating elements from the mains supply. The chek-
ks described may o
on
nlly
y b
be
e p
pe
errffo
orrm
me
ed
d b
by
y a
an
n e
elle
ec
cttrriic
ca
all ffiitttte
err o
orr b
by
y q
qu
ua
alliiffiie
ed
d a
afftte
err--
s
sa
alle
es
s s
se
errv
viic
ce
e p
pe
errs
so
on
nn
ne
ell..
The text below describes fault messages, possible fault causes and the corre-
sponding remedial action.
9
9..1
1
F
Fa
au
ulltt m
me
es
ss
sa
ag
ge
es
s,, p
po
os
ss
siib
blle
e c
ca
au
us
se
es
s a
an
nd
d m
me
ea
as
su
urre
es
s tto
o b
be
e tta
ak
ke
en
n a
as
s rre
em
me
ed
diia
all a
ac
cttiio
on
n
Fault message: p
piillo
ott lla
am
mp
p o
offff
Possible cause: absence of mains voltage.
Remedial action: ensure continued supply of mains voltage.
Fault message: p
piillo
ott lla
am
mp
p fflla
as
sh
hiin
ng
g rre
ed
d
Preventive action before performing any other checks: reset the potentiostat
by separating the device for about 30 seconds from the mains supply in order
to create well-defined starting conditions. Reconnect the mains supply.
If the L
LE
ED
D iis
s s
sttiillll fflla
as
sh
hiin
ng
g rre
ed
d tth
he
erre
ea
afftte
err,, check the following possible fault
causes and perform the measures required as remedial action.
1. The hot-water tank is not filled with water.
Inspection: Check that the hot-water tank is filled completely with water.
Remedial action: if necessary, fill the hot-water tank completely with water.
2. The electrical contact between plug-in potentiostat and anode / tank
connection by means of the connecting cable is not ensured.
Inspection: Check all connections and contacts for perfect electrical continuity.
Remedial action: establish the electrical contact and install a new
connecting cable, if needed.
38