O
Op
pe
erra
attiin
ng
g IIn
ns
sttrru
uc
cttiio
on
n CORREX
®
UP 2.3-919
9. R
Re
eq
qu
uiirre
ed
d ffu
un
nc
cttiio
on
n c
ch
he
ec
ck
k:: The correct polarity must be checked by
measuring magnitude and sign of the drive potential applied with a
DC-voltmeter (e.g. digital multimeter or CorroScout
®
500). For measuring,
the instrument must be set to the 20 V DC range, the negative probe of the
instrument connected to the tank and the positive probe to the titanium
anode. The drive potential applied must be U > +2,3 V DC. Observe the '+'
sign. For this measurement, the tank must be filled with water and the
plug-in potentiostat connected.
N
No
otte
e:: The CORREX
®
UP system becomes functional only after the tank has
been filled with water.
P
Piillo
ott lla
am
mp
p ((1
11
1)) g
grre
ee
en
n:: mains supply established and CORREX
®
UP ready
to operate.
P
Piillo
ott lla
am
mp
p ((1
11
1)) o
offff:: probably no mains voltage.
P
Piillo
ott lla
am
mp
p ((1
11
1)) fflla
as
sh
hiin
ng
g rre
ed
d:: malfunction of the system. In this case, the
checks described in chapter 9 must be performed.
N
No
otte
e:: If the pilot lamp begins flashing right away after the first
installation, it can be assumed that the malfunction is due to inappropriate
installation. Check and eliminate the fault in accordance with the
instructions set out in chapter 9.
7
7..2
2
C
CO
OR
RR
RE
EX
X
®
®
U
UP
P 2
2..3
3--9
91
19
9 ffo
orr iin
ns
su
ulla
atte
ed
d--h
ho
olle
e m
mo
ou
un
nttiin
ng
g
N
No
otte
e:: Observe the instructions set out in chapter 2.3 above.
7
7..2
2..1
1 S
Sa
affe
etty
y iin
ns
sttrru
uc
cttiio
on
ns
s ffo
orr ffiittttiin
ng
g::
1. Remove any existing magnesium protection anode before installing the
CORREX
®
UP system (in case of retrofitting).
2. Never connect the plug-in potentiostat to magnesium protection anodes.
3. The titanium anode must be in direct contact with internal tank components
or with the tank wall. The quality of the insulation must be checked with a
suitable measuring instrument (e.g digital multimeter or CorroScout
®
500).
During this measurement, the titanium anode must not be immersed in water.
4. The function of the CORREX
®
UP system is only ensured if all electrical
parts are safely connected by metallic conductors. The quality of the galvanic
connections must be checked with a suitable measuring instrument (e.g
digital multimeter or CorroScout
®
500).
5. Use only the original connecting cables.
6. Never extend the connecting cables: otherwise risk of connection with
wrong polarity and thus of increased corrosion.
7. Check before commissioning that the cables are not interchanged.
Interchanging the cables results in increased corrosion.
34