Copley Controls Encoder Guide
Absolute Encoders
Copley Controls
13
2.2: Emulated Encoder Output
Copley Controls drives can receive position feedback from sensors on the motor, through the
Primary Feedback channel, and produce emulated digital encoder output using the
drive’s
multimode port.
Below is an example of configuring the drive with an absolute encoder on the motor and producing
an emulated output from the multi-mode port.
1
In CME2, navigate to the
Feedback Options
screen:
Amplifier
Basic Setup
Change
Settings
Next
.
On the
Feedback Options
screen, set
Motor Feedback
to Absolute A, for example.