*This parameter has a maximum range of 250Hz in Unidrive VTC.
Open-loop and Closed-loop Vector
Enter the value from the rating plate of the motor.
6.2.15 Operating-mode selection
The settings for
0.48
are as follows:
See Chapter 8
The operating mode cannot be changed while the drive is running.
6.2.16 Status information
This parameter indicates the current status of the drive parameter
security system. Each digit indicates a particular aspect of security as
follows:
Units digit:
0 = Standard security has been unlocked
1 = Standard security is still set
Tens digit:
0 = User security has been unlocked or is not active
1 = User security is active preventing RW access
Hundreds digit:
1 = Pr
11.30
not equal to 149*
Thousands digit:
1 = Pr
11.30
equal to zero*
* The value of Pr
11.30
is the last value written by the user. Pr
11.30
always appears as 149 when first accessed by the key pad to hide the
real value last written by the user. If Pr
11.30
= 149 then user security is
cleared. If Pr
11.30
= 0 then user security and security preventing
access outside menu 0 is cleared.
In contrast to all the other parameters in menu 0, this parameter does
not exist in any other menu.
Displays the first two sections of the software version of the drive.
6.2.17 Unidrive VTC Menu 0 differences
Menu 0 in Unidrive VTC contains some different parameters to menu 0
in Unidrive. The following menu 0 parameters are found in Unidrive VTC.
Any parameter not listed below is the same as open loop Unidrive.
Pr
0.14
indicates the total motor current (the vector sum of Pr
0.13
Motor
active-current
and Pr
4.17
Motor magnetising current
).
Total output power of the drive (positive for power flow out of the drive
output terminals).
Enter the value of frequency as required. When Pr
1.10
Bipolar
reference select
is set at 0, negative values are treated as zero. When
Pr
1.10
is set at 1, negative values will cause the drive to run in the
reverse direction.
0.47 {5.06}
Motor - rated frequency
RW
Bit
OL
Ú
0 to 1,000.0Hz*
Ö
EUR> 50
USA> 60
CL
Ú
VT> 0 to 1,000.0Hz
SV> 0Hz
Ö
EUR> 50
USA> 60
0
0.48 {11.31}
Drive operating mode
selector
RW
Txt
R
P
Ú
(See below)
Ö
OPEN.LP (0)
Pr 0.48 setting
Operating mode
0
Open-loop
1
Closed-loop Vector
2
Closed-loop Servo
3
For operation in this mode, refer to the
Unidrive Regen Installation Guide
0.49
Security status
RO
Uni
P
Ú
0 to 1,000
Ö
1
0.50 {11.29}
Software version number
RO
Uni
P
Ú
1.00 to 99.99
Ö
0.14 {4.01}
Total motor current
RO
Uni
P
Ú
0 to I
MAX
A
Ö
0.17 {5.03}
Total motor power
RO
Bi
P
Ú
±P
MAX
Ö
0.22
Drive rated current
RO
Uni
P
Ú
2.10 to 202 A
Ö
0.23
Analog input 1 mode selector
RW
Txt
R
Ú
VOLt (0), 0 - 20 (1), 20 - 0 (2),
4 - 20.tr (3), 20 - 4.tr (4),
4 - 20.Lo (5), 20 - 4.Lo (6),
4 - 20.Pr (7), 20 - 4.Pr (8)
Ö
VOLt (0)
Setting
Input signal
When current signal
≤
30mA
VOLt
(0)
±10V
0-20
(1)
0 to 20mA
Signal treated as zero
20-0
(2)
20mA to 0
Signal treated as zero
4-20.tr
(3)
4mA to 20mA
Drive trips
20-4.tr
(4)
20mA to 4mA
Drive trips
4-20.Lo
(5)
4mA to 20mA
Drive runs at minimum or low speed
20-4.Lo
(6)
20mA to 4mA
Drive runs at minimum or low speed
4-20.Pr
(7)
4mA to 20mA
Drive runs at previous speed
20-4.Pr
(8)
20mA to 4mA
Drive runs at previous speed
0.24 {1.21}
Preset frequency 1
0.25 {1.22}
Preset frequency 2
RW
Bi
Ú
±1000.0 Hz
Ö
0.0
NOTE