Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Menu 0
Running
the motor
Optimisation
Macros
Advanced
Parameters
Technical
Data
Diagnostics
UL Listing
Information
138
Unidrive User Guide
www.controltechniques.com Issue Number: 9
* These parameters have a default setting of 120% in Unidrive VTC.
** For more information, please refer to section 10.22.3
*** For more information, please refer to section 10.22.5
Types of current range
FLC
Full load current of the drive (maximum continuous output
current up to 40
o
C ambient temperature). Displayed in Pr
11.32
{
0.33
}.
I
MAX
A
Maximum overload output current of the drive up to 40
o
C
ambient temperature, derived as follows:
Size 1 to 4: OL> 150% x FLC
CL> 175% x FLC
Size 5:
150% x FLC
I
MAX
%
on page 98 for the definition of
I
MAX
%.
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
4.01
Motor current magnitude
0 to I
MAX
A
RO Uni
P
4.02
Motor active-current
{
0.13
}
± I
MAX
A
RO Bi
P
4.03
Torque demand
± I
MAX
%
RO Bi
P
4.04
Current demand
± I
MAX
%
RO Bi
P
4.05
Motoring current limit
0 to I
MAX
%
150*
175
RW Uni
4.06
Regenerating current limit
0 to I
MAX
%
150*
175
RW Uni
4.07
Symmetrical current limit
{
0.06
}
0 to I
MAX
%
150*
175
RW Uni
4.08
Torque reference**
± I
MAX
%
0
RW Bi
4.09
Torque reference offset
± I
MAX
%
0
RW Bi
4.10
Torque reference offset
enable
0 or 1
0
RW Bit
4.11
Torque mode
select
or**
{
0.17
}
0 to 1
0 to 4
0
RW Uni
P
4.12
Current-demand filter time-constant
0 to 250 ms
0
RW Uni
4.13
Current-loop proportional gain***
0 to 30,000
20
150
130
RW Uni
4.14
Current-loop integral gain***
0 to 30,000
40
2,000
1,200
RW Uni
4.15
Motor thermal time-constant
0 to 400.0 s
89.0
7.0
RW Uni
4.16
Motor protection mode
select
0 or 1
0
RW Bit
4.17
Motor magnetizing current
± I
MAX
A
RO Bi
P
4.18
Over-riding current limit
0 to I
MAX
%
RO Uni
P
4.19
Overload accumulator
0 to 100 %
RO Uni
P
4.20
Percentage torque current
± I
MAX
%
RO Bi
P
RO
Read Only parameter
Uni
Unipolar variable parameter
R
Reset required for new value to take effect
Bi
Bipolar variable parameter
S
New parameter-value saved at power-down
RW
Read / Write parameter
Txt
Text variable parameter
P
Protected; forbidden as destination parameter
Bit
Bit parameter
FLC
Full-load current (max. continuous), Pr
11.32
{
0.33
}
Summary of Contents for Unidrive 1 Series