10.17 Menu 17: Large option module set-
up
Where a parameter is represented by a text value, the value in brackets
in the range column is the setting used for serial communications.
10.18 Menu 18: Application menu 1
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
17.01
Option module code
0 to 100
RO Uni
P
17.02
Option module software version
0.00 to 99.99
RO Uni
P
17.03
DPL line number where trip occurred
0 to 32,000
RO Uni
P
17.04
Available resource in %
0 to 100 %
RO Uni
P
17.05
RS485 Address
1 to 99
11
RW Uni
P
17.06
RS485 Mode
0 to 255
1
RW Uni
P
17.07
RS485 Baud rate
300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4),
9600 (5), 19200 (6), 38400 (7), 76800 (8)
4800 (4)
RW Txt
P
17.08
RS485 Parameter pointer 1
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni
P
17.09
RS485 Parameter pointer 2
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni
P
17.10
Serial scaling factor
0.000 to 4.000
1.000
RW Uni
17.11
Clock task tick time
0 to 100 ms
10
RW Uni
P
17.12
Position controller set-up
0 to 255
0
RW Uni
P
17.13
Auto-run
0 or 1
1
RW Bit
17.14
Global run-time trip enable
0 or 1
0
RW Bit
17.15
RS485 Trip enable
0 or 1
0
RW Bit
17.16
IO link RS485 synchronisation source
0 or 1
0
RW Bit
17.17
Trip if parameter write over-ranges
0 or 1
0
RW Bit
17.18
Watchdog trip enable
0 or 1
0
RW Bit
17.19
Non-volatile data save request
0 or 1
0
RW Bit
17.20
Non-volatile data power down save
0 or 1
0
RW Bit
17.21
Enable dumb-terminal mode
0 or 1
0
RW Bit
17.22
LOM set-up parameter
0 or 1
0
RW Bit
17.23
LOM set-up parameter
0 or 1
0
RW Bit
17.24
LOM set-up parameter
0 or 1
0
RW Bit
17.25
LOM set-up parameter
0 or 1
0
RW Bit
17.26
LOM set-up parameter
0 or 1
0
RW Bit
17.27
LOM set-up parameter
0 or 1
0
RW Bit
17.28
LOM set-up parameter
0 or 1
0
RW Bit
NOTE
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
18.01
Application menu 1 read write integer
±32,000
0
RW Bi
S
18.02
to
18.10
Application menu 1 read only integers
±32,000
0
RO
Bi
18.11
to
18.30
Application menu 1 read write integers
±32,000
0
RW Bi
18.31
to
18.50
Application menu 1 read write bits
0 or 1
0
RW Bit
RO
Read Only parameter
Uni
Unipolar variable parameter
R
Reset required for new value to take effect
Bi
Bipolar variable parameter
S
New parameter-value saved at power-down
RW
Read / Write parameter
Txt
Text variable parameter
P
Protected; forbidden as destination parameter
Bit
Bit parameter
FLC
Full-load current (max. continuous), Pr
11.32
{
0.33
}