![Control Techniques Unidrive 1 Series User Manual Download Page 146](http://html.mh-extra.com/html/control-techniques/unidrive-1-series/unidrive-1-series_user-manual_2658692146.webp)
Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Menu 0
Running
the motor
Optimisation
Macros
Advanced
Parameters
Technical
Data
Diagnostics
UL Listing
Information
146
Unidrive User Guide
www.controltechniques.com Issue Number: 9
Where a parameter is represented by a text value, the value in brackets
in the range column is the setting used for serial communications.
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
CL
OL
VT
SV
7.01
Analog input 1
±100.0 %
RO Bi
P
7.02
Analog input 2
±100.0 %
RO Bi
P
7.03
Analog input 3
±100.0 %
RO Bi
P
7.04
Heatsink temperature
0 to 100
o
C
RO Uni
P
7.05
Control board temperature
0 to 100
o
C
RO Uni
P
7.06
Analog input 1 mode
selector
{
0.24
}
VOLt (0), 0 - 20 (1), 20 - 0 (2), 4 - 20.tr (3),
20 - 4.tr (4), 4 - 20.Lo (5), 20 - 4.Lo (6),
4 - 20.Pr (7), 20 - 4.Pr (8)
VOLt (0)
RW Txt R
7.07
Analog input 1 offset trim
±10.000 %
0
RW Bi
P
7.08
Analog input 1 scaling
0 to 4.000
1.000
RW Uni
7.09
Analog input 1
invert
0 or 1
0
RW Bit
7.10
Analog input 1 destination parameter
Pr
0.00
to Pr
20.50
Pr
1.36
RW Uni R
P
7.11
Analog input 2 mode
selector
{
0.25
}
(as Pr
7.06
)
VOLt (0)
RW Txt R
7.12
Analog input 2 scaling
0 to 4.000
1
RW Uni
7.13
Analog input 2
invert
0 or 1
0
RW Bit
7.14
Analog input 2 destination parameter
{
0.26
}
Pr
0.00
to Pr
20.50
Pr
1.37
RW Uni R
P
7.15
Analog input 3 mode
selector
VOLt (0), 0 - 20 (1), 20 - 0 (2), 4 - 20.tr (3) ,
20 - 4.tr (4), 4 - 20.Lo (5) , 20 - 4.Lo (6),
4 - 20.Pr (7), 20 - 4.Pr (8), th.SC (9), th (10)
EUR> th (10), USA> VOLt (0)
RW Txt R
7.16
Analog input 3 scaling
0 to 4.000
1.000
RW Uni
7.17
Analog input 3
invert
0 or 1
0
RW Bit
7.18
Analog input 3 destination parameter
Pr
0.00
to Pr
20.50
Pr
0.00
RW Uni R
P
7.19
Analog output 1 source parameter
Pr
0.00
to Pr
20.50
Pr
5.01
Pr
3.02
RW Uni R
P
7.20
Analog output 1 scaling
0 to 4.000
1
RW Uni
7.21
Analog output 1 mode
selector
VOLt (0), 0 - 20 (1), 4 - 20 (2)
VOLt (0)
RW Txt R
P
7.22
Analog output 2 source parameter
Pr
0.00
to Pr
20.50
Pr
4.02
RW Uni R
P
7.23
Analog output 2 scaling
0 to 4.000
1.000
RW Uni
7.24
Analog output 2 mode
selector
VOLt (0), 0 - 20 (1), 4 - 20 (2)
VOLt (0)
RW Txt R
P
7.25
Calibrate analog input 1 full scale
0 or 1
0
RW Bit
7.26
V/f sample time
0 to 5.0 ms
4.0
RW Uni
7.27
Analog input 1 current-loop loss
indicator
0 or 1
RO Bit
P
7.28
Analog input 2 current-loop loss
indicator
0 or 1
RO Bit
P
7.29
Analog input 3 current-loop loss
indicator
0 or 1
RO Bit
P
7.30
Analog output set-up
enable
0 or 1
0
RW Bit
7.31
UD78 large option module fitted
indicator
0 or 1
RO Bit
P
7.32
IGBT junction temperature
0 to 150 °C
RO Uni
P
RO
Read Only parameter
Uni
Unipolar variable parameter
R
Reset required for new value to take effect
Bi
Bipolar variable parameter
S
New parameter-value saved at power-down
RW
Read / Write parameter
Txt
Text variable parameter
P
Protected; forbidden as destination parameter
Bit
Bit parameter
FLC
Full-load current (max. continuous), Pr
11.32
{
0.33
}
NOTE
Summary of Contents for Unidrive 1 Series
Page 208: ......