Unidrive User Guide
www.controltechniques.com Issue Number: 9
FLC
Full load current of the drive (maximum continuous output
current up to 40
o
C ambient temperature). Displayed in Pr
11.32
{
0.33
}.
I
MAX
A
For definition of I
MAX
P
MAX
Where a parameter is represented by a text value, the value in brackets
in the range column is the setting used for serial communications.
Parameter
Range(
Ú
)
Default(
Ö
)
Type
Regen
Regen
15.01
Supply current magnitude
{
0.11
}
±Maximum drive current A
RO
Bi
P
15.02
Supply voltage
{
0.12
}
400V drive: 0 to 528 V
RO Uni
P
15.03
Supply power
{
0.13
}
± P
max
kW
RO
Bi
P
15.04
DC Bus voltage
{
0.14
}
400V drive: 0 to 830 V
RO Uni
P
15.05
Supply frequency
{
0.15
}
±100 Hz
RO
Bi
P
15.06
Input inductance
{
0.16
}
0.001 to 100 mH
RO Uni
P
15.07
DC Bus voltage set-point
{
0.17
}
400V drive: 0 to 800 V
400V drive: 700
RW Uni
15.08
Switching frequency
{
0.18
}
3 (0), 4.5 (1), 6 (2), 9 (3), 12 (4) kHz
0
RW Txt
P
15.09
High stability space vector modulation
{
0.19
}
0 or 1
0
RW Bit
15.10
Quasi-square operation select
{
0.20
}
0 or 1
0
RW Bit
15.11
Sinusoidal rectifier synchronising
{
0.21
}
0 or 1
RO Bit
P
15.12
Sinusoidal rectifier synchronised
{
0.22
}
0 or 1
RO Bit
P
15.13
Sinusoidal rectifier phase loss
{
0.23
}
0 or 1
RO Bit
P
15.14
Close soft start contactor
{
0.24
}
0 or 1
RO Bit
P
15.15
Soft start contactor is closed
{
0.25
}
0 or 1
RO Bit
15.16
Enable motor drive
{
0.26
}
0 or 1
RO Bit
P
15.17
Line synchronisation trip enable
{
0.27
}
0 or 1
0
RO Bit
15.18
Line synchronisation status
{
0.28
}
SYNC (0), Ph Det (1), Fr Lo (2), Fr Hi (3),
PLL OI (4), PLL Ph (5)
RO Txt
P
15.19
Current control proportional gain
0 to 30,000
110
RW Uni
15.20
Current control integral gain
0 to 30,000
1,000
RW Uni
15.21
Voltage control proportional gain
0 to 30,000
4,000
RW Uni
15.22
Enable extra mains loss detection
0 or 1
0
RW Bit
RO
Read Only parameter
Uni
Unipolar variable parameter
R
Reset required for new value to take effect
Bi
Bipolar variable parameter
S
New parameter-value saved at power-down
RW
Read / Write parameter
Txt
Text variable parameter
P
Protected; forbidden as destination parameter
Bit
Bit parameter
FLC
Full-load current (max. continuous), Pr
11.32
{
0.33
}
3 I
MAX
×
Pr 5.09
1000
-------------------
×
NOTE