EN
W415-1283 / F / 04.30.18
29
electrical information
6.0 electrical information
ELECTRICAL
COVER
CABLE
CONNECTOR
L1
(BLACK)
L2
(WHITE)
GROUND
(GREEN)
CONTROL BOX
WIRE
NUTS
GROUND
(GREEN)
3 PRONGE
RECEPTACLE
ELECTRICAL BOX
(BLACK)
(WHITE)
WIRE
NUTS
3 PRONG
RECEPTACLE
GROUND
(GREEN)
L2
(WHITE)
L1
(BLACK)
ELECTRICAL
BOX
CABLE
CONNECTOR
Ensure that the transformer is plugged into the receptacle.
note:
!
WARNING
• Do not use this appliance if any part has been under water. Call a qualifi ed service technician immediately to
have the appliance inspected for damage to the electrical circuit.
• Risk of electrical shock or explosion. Do not wire 110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
• All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes. In the
absence of local codes, use the current CSA22.1 Canadian Electric Code in Canada or the current National
Electric Code ANSI/NFPA NO. 70 in the United States.
• Always light the pilot whether for the fi rst time or if the gas supply has run out, with the glass door opened or
removed.
43.1
It is necessary to hard wire this appliance.
Permanently framing the appliance with an enclosure, requires the appliance junction box to be hard wired.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence of
local codes, use the current CSA C22.1 Canadian electrical code in Canada or the ANSI/NFPA national electrical
code in the United States.
6.1 hard wiring connection
6.2 receptacle wiring diagram
6.3 electronic wiring diagram