W415-1283 / F / 04.30.18
47
finishing
10.14 anti-condensation switch
This appliance has the ability to switch from an
electronic intermittent pilot ignition (IPI) to a standing
pilot (ACS) for cold climates. The heat generated by
the standing pilot will improve the start up operation
on colder climate days. Therefore we recommend
switching to the standing pilot on those colder days.
The anti condensation switch (standing pilot) is located
in the control compartment. Using your finger, flip the
switch up for standing pilot, or down for intermittent
pilot ignition.
INSTALLER NOTE:
Some jurisdictions may
prohibit the use of a
standing pilot. In these
jurisdictions the anti
condensation switch
shall be disconnected
to comply with local
codes. To disconnect
locate the white
connector at the end
of the white and blue
wires of the ACS switch
and disconnect.
PANEL COVER
CONTROL
PANEL COVER
PANEL COVER
CONTROL
PANEL COVER
End safety barrier must be removed before accessing the anti-condensation switch, see "end safety barrier
removal / installation (CBHD4P only)" section for detailed instructions.
note: