W415-1283 / F / 04.30.18
EN
8
general information
1.1 rating plate / lighting instruction location
RATING PLATE BHD4
TITLE:
REVISION:
A: CORRECTED ADHESIVE TEMP. LIMIT; UPDATED CSA DATE & DESCRIPTION || 09.07.17_C.L.
DWG #:
DATE:
W385-1936 / A
PAGE 1 OF 2
C E R T I F I E D
CBHD4N
CBHD4P
W385-1936
02.28.14
MAX SIZE:
8 1/2” X 4 3/4”
MATERIAL:
CLASS III A-2, PERMANENT LABEL, 6 MIL
THICKNESS TOTAL, LEXAN, WATER
PROOF, NON-WATER SOLUBLE ADHE -
SIVE, CAPABLE OF WITHSTANDING A
MAXIMUM TEMPERATURE OF 175°F (79°C)
LETTERING:
BLACK LETTERING ON WHITE BACKGROUND
A
MIN. LETTERING FOR “NOT FOR USE WITH SOLID FUEL”,”UN
COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI.”
TO BE 10 PT ARIAL NARROW, BOLD FACE, UPPER CASE. SERIAL
NUMBERS TO BE ASCENDING FROM BHD4005814
CONFORMS TO / CONFORME AUX: ANSI Z21.50 - 2016, CERTIFIED TO / CERTIFIÉ CSA 2.22 - 2016 VENTED DECORATIVE GAS APPLIANCE / FOYER À GAZ VENTILÉ
VENTED GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART
3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A. FOYER À
GAZ VENTILÉ. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ EN VIGEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE SÉCURITÉ ET DE CONSTRUC-
TION DE MAISONS MANUFACTURÉE, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D’ÉTATS-UNIS NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE
MESURES DE SÉCURITÉ CONTRE L’INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. THIS APPLIANCE MUST BE INSTALLED IN
ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE CURRENT ANSI Z223.1 OR CSA B149, INSTALLATION CODES. INSTALLER L’APPAREIL SELON LES CODES D’INSTALLATION ANSI Z223.1 OU
CSA-B149 EN VIGUER.
THIS VENTED GAS FIREPLACE IS
NOT FOR USE WITH AIR FILTERS.
NOT FOR USE WITH SOLID FUEL.
FOR USE WITH GLASS DOORS
CERTIFIED WITH THIS APPLIANCE
ONLY.
CERTIFIED FOR / CERTIFIEE
POUR CANADA / USA
REFERENCE # 161746
WARNING:
DO NOT ADD ANY MATERIAL
TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USE AS A
HEATING APPLIANCE
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS:
TOP 0”
FLOOR 0”
SIDES 0”
BACK 0”
VENT TOP
3”
VENT SIDES & BOTTOM
2”
VERTICAL VENT
1”
MANTEL 8”*
TOP SIDES & BACK: PER STAND OFF SPACERS FOR FRAMING
MATERIALS. FOR FINISHING MATERIALS, SEE OWNER’S MANUAL
*MAXIMUM HORIZONTAL EXTENSION / L’EXTENSION HORIZONTALE
MAXIMALE: 2”. SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.
SEE OWNER’S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM LENGTHS.
ELECTRICAL RATING: 115V.60HZ. LESS THAN 12 AMPERES
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
SPÉCIFICATIONS ÉLECTRIQUES : 115 V,
60HZ. MOINS DE 12 AMPÈRES.
BHD4N
BHD4P
MODEL PROPANE /
PROPANE MODÈLE
CET FOYER À GAZ VENTILÉ N'EST
PAS POUR L'USAGE AVEC LES
FILTRES D'AIR.
UN COMBUSTIBLE SOLIDE NE PAS
ÊTRÉ UTILISÉ AVEC CET APPAREIL.
UTILISER AVEC LES PORTE VITRÉES
HOMOLOGUÉES SEULEMENT AVEC
CETTE APPAREIL.
ADVERTISSEMENT :
N’AJOUTEZ PAS À
CET APPAREIL AUCUN MATÉRIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVECT CET
APPAREIL PAR LE FABRICANT.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME
APPAREIL DE CHAUFFAGE
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX
COMBUSTIBLES :
DESSUS 0”
PLANCHER 0”
CÔTÉS 0”
ARRIÈRE 0”
DESSUS DU CONDUIT D’EVENT
3”
CÔTÉS ET DESSOUS DU CONDUIT
D’EVENT
2”
CONDUIT D’EVENT VERTICAL
1”
TABLETTE 8”*
DESSUS, CÔTÉS & ARRIÈRE : SELON LES ESPACEURS DE
DÉGAGEMENT POUR LES MATÉRIAUX D’OSSATURE SELON
LA MANUEL DE PROPRIÉTAIRE POUR LES MATÉRIAUX DE
FINITION. *L’EXTENSION HORIZONTALE MAXIMALE : 2”.
RÉFÉRER AU MANUAL D’INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES. RÉFÉRER AU MANUEL
D’INSTALLATION DE PROPRIÉTAIRE.
MODEL NATURAL GAS /
GAZ NATUREL
0-4500FT (0-1370M)
ALTITUDE / ÉLÉVATION
0-4500FT (0-1370M)
30,000 BTU/H
INPUT / ALIMENTATION
30,000 BTU/H
23,000 BTU/H REDUCED INPUT / ALIMENTATION RÉDUITE 23,000 BTU/H
3.5” WATER COLUMN/D’UNE COLONNE D’EAU
MANIFOLD PRESSURE /
10” WATER COLUMN/D’UNE COLONNE D’EAU
PRESSION AU COLLECTEUR
4.5“ WATER COLUMN/D’UNE COLONNE D’EAU
MINIMUM SUPPLY PRESSURE /
11” WATER COLUMN/D’UNE COLONNE D’EAU
PRESSION D’ALIMENTATION MINIMALE
7.0“ WATER COLUMN/D’UNE COLONNE D’EAU
MAXIMUM SUPPLY PRESSURE
13” WATER COLUMN/D’UNE COLONNE D’EAU
PRESSION D’ALIMENTATION MAXIMALE
67.9%
P.4
67.9%
SERIAL NUMBER/ NO. DE SÉRIE:
BHD4
L’APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT
L’ENSEMBLE D’ÉVACUATION PROPRE À NAPOLEON. RÉFÉRER
AU MANUEL D’INSTALLATION DE PROPRIÉTAIRE POUR
L’ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BIEN
RÉINSTALLER ET RESCELLER L’ÉVENT APRÉS AVOIR ASSURÉ
LE MAINTIEN DU SYSTÉME DE PRISE D’AIR.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE
NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR
INTAKE SYSTEM.
A
Both the rating plate and lighting instructions are attached to a cable and located behind the control panel of the
appliance. Lift the access plate and control panel up and away from the appliance. With the cable at the bulb end of
the slot, wiggle the rating plate out being careful not to tear the instructions.
This illustration is for reference only. Refer to the rating plate on the appli-
ance for accurate information.
SAMPLE
!
WARNING
• Allow the appliance to cool before performing any maintenance or cleaning.
1.2 mobile home installation
This appliance must be installed in accordance with the manufacturer’s instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home
Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas
indicated on the rating plate.
This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Built
in appliances are equipped with 1/4” (6.4mm) diameter holes located in the front left and right corners of the base.
Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact your
local authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance must
be fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot and
the fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting the
appliance, ensure that the logs are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certifi ed kit is used.
Conversion Kits
This appliance is fi eld convertible between Natural Gas (NG) and Propane (P).
To convert from one gas to another, consult your Authorized dealer/distributor.
20.1
note:
Conversion kits are not available for Vent Free appliances.
note:
Screen must be removed to access rating plate / lighting instructions.
note:
The rating plate must remain with the appliance at all times. It must not be
removed.