Summary of Contents for Ulys 1100

Page 1: ...APPLIANCE o Model o Series number o Date of purchase Installation guide User guide please keep R f 01 2012 Ulys IMPORTANT IT IS RECOMMENDED TO NOTE THE SERIAL NUMBER AND TO WRITE IT DOWN IN THE BOX AB...

Page 2: ......

Page 3: ...53336 1 BF53336 1 1 16 BF53335 1 BF53335 1 BF53335 1 BF53335 1 BF53335 1 BF53335 1 1 17 BI11854 4 BI11854 4 BI11854 4 BI11854 4 BI11854 4 BI11854 4 1 18 BF53352 1 BF53352 1 BF53352 1 BF53352 1 BF53352...

Page 4: ......

Page 5: ...7258 1 9 BF58276 BF55276 BF56276 BF53276 BF55276 BF53276 1 10 40240 1 40240 1 40240 1 40240 1 40240 1 40240 1 1 11 BF58252 BF55252 BF56252 BF53252 BF57252 BF18252 1 12 BF40214 BF40214 BF40214 BF40214...

Page 6: ...ULYS600 ULYS700 ULYS800V ULYS900...

Page 7: ...BF53380 1 BF57380 BF518380 1 BF40101 1 1 1 1 2 2 2 BF40102 1 1 1 1 2 2 3 BF53361 1 1 1 4 BF53372 1 5 BF53369 2 2 2 6 BF53367 2 2 2 7 BF53364 1 1 1 8 BF53360 1 9 BF53363 1 10 BF53366 2 2 11 BF53368 2 2...

Page 8: ...ULYS 600...

Page 9: ...ULYS 700...

Page 10: ...ULYS 800V...

Page 11: ...ULYS 900...

Page 12: ...ULYS 1100...

Page 13: ...ULYS 1100 XXL...

Page 14: ...0 12 0 01 0 11 0 16 0 02 0 13 Emissions de CO mg m3 0 13 O2 1635 1533 146 1298 1919 238 1576 Consommation Bois kg h 3 04 2 53 2 59 3 58 4 32 3 96 3 81 Temp rature moyenne des fum es C 250 290 263 251...

Page 15: ...m 644 mm 200 kg ULYS 1100 1165 mm 996 5 mm 644 mm 270 kg ULYS 800V 764 mm 1365 mm 644 mm 200 kg ULYS 600 684 mm 1852 mm 650 mm 244 kg ULYS XXL 1165 mm 1217 mm 647 mm 325 kg For manufacturing reasons d...

Page 16: ...NSTALLATION OF THE FIREBOX 17 1 4 2 FITTING AND LEVEL CONTROL 18 1 4 3 MINIMUM DIMENSIONS OF THE FIREPLACE 19 1 4 4 FLOOR 19 1 5 VENTILATION OF THE HOOD 20 1 5 1 CONVECTIVE AIR INLET 20 1 5 2 CONVECTI...

Page 17: ...14 2 8 5 SEALING JOINTS 25 2 8 6 CHIMNEY SWEEPING 2 8 7 ANNUAL SERVICE 26 3 3 CONTRACTUAL WARRANTY 27 4 4 ANNEXES 28 4 1 OPERATION DIAGNOSTIC 28 4 2 FROM TREE TO FIRE 29...

Page 18: ...French Scientific and Technical Buildling Centre Since this fireplace is in compliance with current standards it is strictly forbidden to modify the appliance in any way 1 2 CHIMNEY FLUE In the case o...

Page 19: ...er the top of the chimney must be above the roof ridge by at least 40 cm In any case and in order for the fireplace to operate properly the draft TI of the duct must be between 10 and 30 Pa 1 to 3 mm...

Page 20: ...of outside air specifically for the fireplace operation must be added 1 4 INSTALLATION AND MINIMUM DIMENSIONS OF THE FIREPLACE 1 4 1 INSTALLATION OF THE FIREBOX It is important to follow our recommend...

Page 21: ...en devissant les vis de fixation 2 pour chaque poign e afin de lib rer les contres poids et ainsi pouvoir manoeuvrer la porte 1 4 2 FITTING AND LEVEL CONTROL In order to lighten the appliance and faci...

Page 22: ...he door Locking of the nuts is done with the firebox standing ATTENTION PREPARE THE OUTSIDE AIR INLET BEFORE INSTALLING THE FIREPLACE 1 4 3 MINIMUM DIMENSIONS OF THE FIREPLACE The appliance must be su...

Page 23: ...VE AIR INLET It is compulsory to build an inlet of convective air at the base of the firebox This inlet must have a minimum nominal section of E cm2 actual surface of air passage Even if the air entry...

Page 24: ...heet The aluminium sheet is to be placed on the side of the heat source This insulant must be able to sustain a continuous temperature of 600 C It can be ordered at your local FONDIS retailer or at FO...

Page 25: ...duct with technical notice exclusively use the REDI FONDIS adaptative part to imperatively attach to the firebox nozzle Ref REDI vent diam flexible casing inside diam Ex REDI2320 PRINCIPLE OF CASING...

Page 26: ...extinguished the installation must be checked by a specialist before any fur ther use 2 2 FIRST FIRES Thus for the first fires it is important to progressively increase the temperature of the applianc...

Page 27: ...s to very slow operation corresponding to reduced regime We advise against using the firebox permanently in reduced mode This mode of operation can lead to significant condensation and bistre in the a...

Page 28: ...nditions de fined by the current standard and using dry fire wood beech hornbeam Only com pressed lignite briquettes may be used as a substitute The wood you use must be dry i e its humidity rate must...

Page 29: ...wood influence the volume of ashes produced 2 8 4 PAINT Paint touch ups can be made by the user with the Fondis high temperature paint minimum 500 C which can be purchased at the Support Centre 2 8 5...

Page 30: ...interior of the installation hood dressing and the hot air circulation vents lattices at the start of the heating season and regu larly during the heating period in order to avoid any risk of overheat...

Page 31: ...e is to the advantage of the buyer not exclusive of the legal guarantee for hidden defects and faults which applies according to the conditions of arti cles 1641 ff of the civil code CONTRACTUAL GUARA...

Page 32: ...SE THE LOAD IN THE FIREBOX USE WOOD THAT IS DRIER INCREASE THE OPENING OF COMBUSTION AIR INLETS CHECK THE STATE OF TIGHTNESS SEALS OF THE DOOR MAKE SURE THE HOT AIR CIRCULATION IS NOT PERTURBED IMPORT...

Page 33: ...y fire The fire starts better if the air from the duct is warmed up In order to do this crumple not too much some paper not from ads or magazines which contain polluting inks lay dry twigs kindling so...