Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.
2.4 RATING PLATE INFORMATION
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2014, CERTIFIED TO / CERTIFIE CSA 2.22-2014 VENTED GAS FIREPLACE / FOYER À GAZ VENTILÉ.
DIRECT VENT GAS FIREPLACE. SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM FOYER À GAZ VENTILÉ DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER,
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS
IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.
APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED
DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME
HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
FOR USE WITH BARRIER
RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS
W565-0154. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
POUR
UNE UTILISER AVEC BARRIÈRE W565-0154. SUIVEZ LES INSTRUCTIONS
9700539 (WSL)
4001657 (NGZ)
D'INSTALLATION SE TROUVENT DANS LE MANUEL D'INSTALLATION
4001658 (NAC)
4001659 (WUSA)
B30NTR CB30NTR MODEL CB30PTR B30PTR
B30NTRE CB30NTRE CB30PTRE
B30PTRE
0-4500FT (0-1370m)
ALTITUDE / ELEVATION
0-4500FT (0-1370m)
15,000 BTU/h
INPUT / ALIMENTATION
15,000 BTU/h
10,000 BTU/h REDUCED INPUT / ALIMENTATION REDUITE 11,500 BTU/h
MANIFOLD PRESSURE:
3.5" (9MB) WATER COLUMN
MANIFOLD PRESSURE:
10" (25MB) WATER COLUMN
PRESSION AU COLLECTEUR:
3.5" (9 MB) D'UNE COLONNE D'EAU
PRESSION AU COLLECTEUR:
10" (25MB) D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE:
4.5" (11MB) WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" (27MB) WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE:
4.5" (11MB) D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MINIMALE:
11" (27MB) D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE:
7.0" (17MB) WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" (32MB) WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE:
7.0" (17MB) D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MAXIMALE:
13" (32MB) D'UNE COLONNE D'EAU
P4:
44%
P4:
44%
NOT FOR USE WITH SOLID FUEL. FOR USE WITH GLASS DOORS
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
CERTIFIED WITH THIS UNIT ONLY.
APPAREIL. UTILISER AVEC LES PORTES VITREES HOMOLOGUEES
WARNING:
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE
SEULEMENT AVEC CETTE UNITE.
ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE FLAMES,
AVERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION RAPIDE.
OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. MINIMUM CLEARANCE
REMPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL LTÉE.
TO COMBUSTIBLE MATERIALS /
N’AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
TOP/ DESSUS
0
RECESSED DEPTH / PROFONDEUR D'ENCASTRE
14 ½"
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE
WOLF STEEL VENT KITS. SEE OWNERS FLOOR / PLANCHER
0
VENT SIDES / COTES DE L'EVENT
1"
INSTALLATION MANUAL FOR VENTING
SPECIFICS. PROPER REINSTALLATION AND RESEALING IS SIDES / COTES
0
VENT TOP / EVENT SUPERIEUR 3"
NECESSARY AFTER SERVICING THE VENT-AIR
INTAKE SYSTEM.
BACK / ARRIERE
0
VENT BOTTOM / EVENT INFERIEUR
1"
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON.
MANTEL / MANTEAU
12" *
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST
* MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 2". SEE INSTRUCTION
IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE
LE MAINTIEN DU MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES
SYSTEME DE PRISE D'AIR.
EXTENSIONS PLUS GRANDES.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING
APPLIANCE SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM AND MAXIMUM VENT LENGTHS.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPPAREIL DE CHAUFFAGE.
REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR LES LONGUEURS
D'EVACUATION MINIMALE ET MAXIMALE.
ELECTRICAL RATING / CLASSIFICATION: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: EP35
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
SERIAL NUMBER/NO. DE SERIE:
B30
W385-1951
/ C
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
A barrier designed to reduce the risk of burns from the hot viewing glass, is provided with the
appliance and shall be installed.
Summary of Contents for CB30NTR
Page 11: ...11 EN W415 1398 C 06 15 17 3 2 TYPICAL VENT INSTALLATION...
Page 12: ...12 EN W415 1398 C 06 15 17 See VENTING section...
Page 42: ...42 EN W415 1398 C 06 15 17 5 1 MINIMUM FRAMING DIMENSIONS...
Page 46: ...46 EN W415 1398 C 06 15 17 MAXIMUM REAR VENT CLEARANCES EXAMPLE 1...
Page 83: ......
Page 84: ......